EasyManua.ls Logo

North Star 5044310 - Page 10

Default Icon
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Initial Setup
11. Turn motor on and use control valve handle to extend and retract wedge five (5)
times
to remove air from the high-pressure lines.
12. With wedge retracted, check oil level again. Fill if necessary.
WARNING: NEVER remove the hydraulic oil fill cap when the motor is on.
Hot oil can escape causing severe burns. Allow log splitter to cool completely
before removing hydraulic oil fill cap.
Note: If the log splitter will be run for long periods of time in outdoor temperatures
above 70°F, we recommend changing the hydraulic oil to DEXTRON III.
Step Three:
Lubricate Keepers
Pump grease into grease zerks found under each keeper. This will help prevent
wear between the keepers and beam.
Grease
Zerks
Note: Log Cradle is not
shown in picture below for
better viewing purposes.