OLXE 03/10
13
Sensing Output Frequency 50 Hz 60 Hz
Voltage 100 Volt Class 100V (86.5V~110V~120V) 120V
200 Volt Class 200V (173V~220V~240V) 240V
Phase: Single Phase Single Phase
Power Input Voltage: 100V ~ 127V ~ 139V
Frequency: 50 Hz / 60 Hz
Phase: Single Phase Single Phase
Sensing Output Max. Voltage: 87% of Power Input Voltage (DC Voltage)
(F+) – (F-) Continuous Current: Maximum 3A Current
Current Maximum Forcing: 9A forcing 1 to 5 seconds at 25°C
Field Resistance: Minimum 15 Ohms
Voltage Adjust Range Minimum ±5% of Normal Voltage
Volt/ Hertz Characteristic 57 Hz in 60 Hz operation mode, 47 Hz in 50 Hz operation mode
Voltage Build-Up Self-Building Up at over 6V Power Input Voltage
Voltage Changeable Rate Maximum ±1.5%
Temperature Drift Within ±0.02%/ degree C
Operating Temperature -4°F (-20°C) to 140°F (60°C)
Storage Temperature -4°F (-20°C) to 158°F (70°C)
Outside Dimension 5.6" x 4.0" x 1.57" (140mm x 100mm x 40 mm)
Weight 1.4 lbs. (0.65 kgs)
Automatic Voltage Regulator: DST-100-2FAK