GENERAL
The System Sensor FSB-200 and FSB-200S are intelli-
gent, addressable projected beam smoke detectors for pro-
tecting open areas with high and sloping ceilings, and wide-
open areas, where spot-type smoke detectors are difficult
to install and maintain. Ideal applications are atriums, ca-
thedral ceilings, aircraft hangers, warehouses, sporting are-
nas, concert halls, and enclosed parking facilities. They
are compatible with the NFS-3030 and NFS-640 in
FlashScan® or CLIP mode, as well as legacy products like
the AM2020, AFP1010, AFP-400, AFP-300, AFP-200, and
AFP-100 (CLIP mode). Installation of the single-ended re-
flective design is much quicker than a dual-ended projected
beam detector. Alignment is easily accomplished with an
optical sight and a two-digit signal strength meter incorpo-
rated into the beam detector. Listed for operation from –
22°F to 131°F, the FSB-200 and FSB-200S are usable in
open area applications where temperature extremes ex-
ceed the design limits of other types of smoke detection.
The FSB-200 and FSB-200S are a transmitter/receiver unit
and a reflector. When smoke enters the area between the
unit and the reflector it causes a reduction in the signal
strength. When the smoke level (signal strength) reaches
the predetermined threshold, an alarm is activated. The
detectors have four standard sensitivity selections as well
as two Acclimate Plus™ settings. When either Acclimate
Plus™ setting is selected, the detector’s advanced soft-
ware algorithms automatically adjust to the optimum sen-
sitivity for the specific environment. The protection range
is 16 to 328 feet and there are built-in isolators for Style 7
operation.
The FSB-200S has an integral sensitivity test feature of a fil-
ter attached to a servomotor inside the detector optics. Acti-
vation of the RTS451 remote test station moves the filter into
the pathway of the light beam, testing the detector’s sensitiv-
ity. This sensitivity test feature allows the user to quickly and
easily meet the annual maintenance and test requirements of
NFPA 72, without physical access to the detector. The servo-
motor must be powered by +24 VDC, not SLC power.
FEATURES
Transmitter/receiver built into same unit.
Six user-selectable sensitivity levels.
16' to 328' (use BEAMLRK beyond 230') protection range.
Removable plug-in terminal blocks.
Digital display — no special tools required.
Built-in automatic gain control compensates for signal
deterioration from dust buildup.
Optional remote test station.
Section: Intelligent/Addressable Devices
DN-6985 • H-212
This document is not intended to be used for installation purposes. We try to keep our
product information up-to-date and accurate. We cannot cover all specific applications or
anticipate all requirements. All specifications are subject to change without notice. For
more information, contact NOTIFIER.Phone: (203) 484-7161 FAX: (203) 484-7118
12 Clintonville Road, Northford, Connecticut 06472
NOTIFIER® is a Honeywell company.
FSB-200(A) and FSB-200S(A)
Single-Ended, Reflected-Type
Addressable Beam Smoke Detectors
April 14, 2005
FSB-200
with
Reflective
Plate
FSB-200 with
BEAMMMK
Optional long-range kit (BEAMLRK) for applications in
excess of 230' (70 m).
Optional multi-mount kit (BEAMMMK) providing ceiling
or wall mount capability with increased angular adjust-
ment.
Optional heater kits (BEAMHK and BEAMHKR) for pre-
vention of condensation (not intended to increase or re-
duce the specified operating temperature).
Acclimate Plus™ is a trademark of NOTIFIER.
S2522
(FSB-200,
FSB-200S)
California
State Fire
Marshal
7260-0028:228
MEA
95-04-E
Permit # 2167
MARYLAND
State Fire Marshal
S911 Vol. 109/
CS308 Vol. 35
(FSB-200A,
FSB-200SA)
Question and Answer IconNeed help?

Do you have a question about the Notifier FSB-200 and is the answer not in the manual?

Notifier FSB-200 Specifications

General IconGeneral
Operating Voltage Range15 to 32 VDC
Height (with B210LP base)2.0 inches (51 mm)
Air Velocity0 to 4000 ft/min (0 to 20 m/s)
Operating Temperature Range0°C to 49°C (32°F to 120°F)
Humidity10% to 93% non-condensing
Sensitivity2.5%/ft nominal

Summary

General Product Overview

Features

Key features of the FSB-200 and FSB-200S beam smoke detectors, including transmitter/receiver unit, sensitivity levels, and range.

Product Specifications

Operational Specifications

Details operational parameters such as protection range, adjustment angle, and sensitivity levels for beam detectors.

Environmental Specifications

Specifies the operating temperature and humidity range for the beam smoke detectors.

Electrical Specifications

Outlines voltage, current, and power consumption details for the beam smoke detectors and accessories.

Mechanical Specifications

Provides dimensions for the detector and reflector units used in beam smoke detection systems.

Smoke Detector Spacing Guidelines

Recommendations for spacing beam smoke detectors based on ceiling height and NFPA 72 standards.

Sensitivity and Wiring

Sensitivity Settings Explained

Details the six sensitivity levels, including percent obscuration, display reading, and acceptable distance ranges.

Acclimate Plus™™ Settings

Explains the two Acclimate Plus™™ settings for automatic sensitivity adjustment based on environment.

Total Obscuration Conversion

Chart converting total obscuration percent per foot for all acceptable sensitivity settings.

Detector Wiring Diagram

Wiring diagram for the FSB-200/FSB-200S detectors, showing connections to panel and next device.

Switch Locations

Diagram showing the location of code switches and isolator shunts on the detector.

Wiring Diagram with RTS451/KEY

Wiring diagram illustrating connections for the FSB-200/FSB-200S with the RTS451/KEY remote test station.

Installation and Product Details

Alignment Adjustment Locations

Identifies key locations for alignment adjustment on the beam smoke detector unit.

Housing Screw Locations

Diagram indicating the positions of screws for accessing the detector housing.

Parts List

List of components included with the beam smoke detector system.

Product Line Information

Details on available models and accessory kits for the beam smoke detector system.

Accessories

Overview of optional accessories like remote test stations and mounting kits.

Related product manuals