or will not remain running
Low fuel levels Add fuel to fuel tank
Selector switch in wrong position Confirm selector switch in appropriate position
Air in fuel line Drain fuel through drain port until air bubbles are all pushed out.
Excessive fuel in cylinder Turn SWITCH to ‘SERVICE’ position and try starting engine. After a few pulls, or after engine
starts up and then stops, turn SWITCH to ‘RUN’ position in for appropriate fuel and re-start.
Oil alert system Ensure correct oil levels
Low batteries If LEDs on UI board do not illuminate, re-
charge the batteries according to the instructions in
the “JUMP START” section of this guide.
Weak/no spark Remove and dry off spark plug
Other Contact Novatio Engineering, Inc.
2. Engine operating but not producing AC power
GFCI disconnected Reset GFCI
Overload Reduce load (if load is already below 1250W, contact Novatio Engineering)
Other See troubleshooting for “rough operation and unsteady AC voltage”
TROUBLESHOOTING