38
temperature control
independent control of metal and elastomer roller, fast response, no liquids, precision
platinum probes are placed in metal and elastomer rollers close to surface, self-
calibrating by internal references
setting range 20 to 40 °C
accuracy 0.05 °C
setting time to 0.1 °C accuracy < 3 min
water bath obsolete
power supply
Operation voltage 100 - 250 V, 50 – 60 Hz
Power consumption < 200 VA
dimensions, weight
L x W x H 36 x 28 x 27 ccm
Weight 20 kgs
computer
Interface to AlphaTackPlus USB 2.0
Operating system Windows 10
software WinAlphaTACK provided with the
measuring system