Novomatics Operation Manual AlphaTackPlus
37
11. Technical specification
Conception
Two slim - roller measurement system. Robust metal case consisting of anodized aluminum
and stainless steel components. Sensitive measurement devices are completely
encapsulated. User friendly measurement control by WinAlphaTack PC-software via USB
interface.
tack force measurement
Sensing Principle inertial free solid-state force sensor, seamlessly
integrated in the metal roller
Pressure measurement range -500 to 500 kN/m2
LineTack measurement range 0 to 500 N/m
Sampling rate up to 120.000 s
-1
Relative accuracy < 1 %
Info: Low tack newspaper inks may have a linetack down to 20 N/m, heatset inks may have a linetack
of 120 N/m, high tack varnishes may have a linetack of up to 300 N/m
roller system
two roller slim system, consisting driven metal roller and engaged, oscillating elastomer roller
metal driving and measuring roller 120 – 1800 rpm (30 – 450 m/min),
higher speeds on request, embedded
tack measuring and temperature
measuring device, self calibrating over
instrument life time
elastomer impression and
distribution roller embedded temperature measuring
device, self calibrating over instrument
life time
hybrid elastomer material usable for
conventional and UV curing samples,
pure UV materials on request, easy
roller exchange
elastomer oscillation rate 0.5 – 3 s-1
elastomer oscillation amplitude 0.5 – 3 mm
lineforce setting
Range 300 – 1000 N/m,
standard 500 N/m