17


  


 
COM
2 DIRIN
3 5VDC
4  ―
5  ―
6 STOP(+)
7  ―
8 ERR(+)
9  ―
10 GND1
11 VCC
12 LOAD(+)
13 LOAD(-)
14 START
15  ―
16  ―
17  ―
18 ‐COM
19 PULSE
20  ―
21  ―
22  ―
23 VR
24  ―
25 SPEEDV

CommonInputSignal
Source
RotationDirection
SettingSignal
BaseBias
    ―
    ―
StopRotating
    ―
TripSignal
    ―
AnalogPowerSource
Ground
PowerSourcefor
AnalogSignal
LOADSignal
LOADSignal(Earth)
RotationStartCommandSignal
―
―
―
TripSignal
RotationPulse
―
―
―
MotorSpeedControl
Voltage
―
MotorSpeedMonitor
Voltage
CommonSignal(DIRIN,START)
24VDCNODipoleMomentInputtosetRotationDirection.
PhotoCouplerBiasPowerSource
NotUsed
NotUsed
Whilemotorisrotated,PhotoCouplerTransistorisON.When
motorisstopped,PhotoCouplerTransistorisOFF.
NotUsed
WhenErrorsOccur(Overload,MotorCordisdisconnected)
NotUsed
UnitInternalGround(+10VGround)
SpeedDirectionVoltage(VR)SignalPowerSource.Output
+10VDC.
LoadSignalOutput(0-15VDC)
GND(LOAD)
Input24VDCtorotatethemotor.
NotUsed
NotUsed
NotUsed
Commonfor(Pins6,8,19)
RotationPulse(PhotoCouplerOutputTTLLevel)24PulseOutput/1revolution
Output/1rotation
NotUsed
NotUsed
NotUsed
RotationSpeed(0V-10VDCInput)At10V,50,000min
-1
or80,000min
-1
NotUsed
Whenmotorisrotated,MotorSpeedcanbemonitored.
Outputvoltageisproportionaltomotorspeed.
Input
Input
Input
―
―
output
―
output
―
output
output
output
output
Input
―
―
―
output
―
―
―
Input
―
output
Common
ON(24V);
ReversedRotation
5VDC
―
―
OFF(OPEN):Stop
―
ON(Closed):Trip
―
InternalGND
10VDC
0-15VOutput
GND
ON(24V):Rotation
―
―
―
ON(24V):Trip
24Pulse/Rotation
―
―
―
0-10VDC
―
0-8VDC
 ②
  
(1)DIRIN(RotationDirectionSettingSignal)andSTART(RotationStartCommandSignal)(CN2:
Pin1,Pin2,Pin14)
Pin1 :CommonforPin2&Pin14
Pin2:When+24VDCissuppliedtotheRotationDirection
SettingSignal(DIRIN),Motorrotates
counterclockwise.WhenPin2isdisconnectedor
voltageisnotsupplied,Motorrotatesclockwise.
Pin14:When+24VDCissuppliedtotheRotationStatrtCommand
Signal(START),themotorstartsrotating,If0VDCis
suppliedorifthelineisdisconnectedthemotorstops.
Comcanbeeither(+)or(-),ifusing(+)commonuse(-)on
Pins2and14.

24V(10mA×2circuits)isneededforpowersource.

Pin14
(START)
3KΩ
3KΩ
510Ω
510Ω
Pin1
(COM)
Pin2
(DIRIN)
     
   

Questions and Answers: