1
・
Simple Manual
Small Sized Frequency Variable Controller
High Function Type
K-ECG25 (Control capacity 2A)
K-ECJ45 (Control capacity 4.5A)
Introduction
Thank you for your purchase of NTN small sized frequency variable controller (High function type). For correct and
safe operation of the controller, please read without fail ‘Precautions for safety’ in the separate operation manual
carefully before use.
1.Vibration sensor K-P1398 (Refer to P. 13 of operation manual)
<Installation direction of vibration sensor>
As the vibration direction of sensor is predetermined (Arrow mark printed on
sensor is the travel direction of work), please note the installation direction.
When it is not possible to match the direction of arrow mark to the forwarding
direction of work, please install it in the reverse direction and reverse the polarity
with the function J07.
Note) There is a case that it become to reverse direction depending on
vibrator.
2.Outside view (Refer to P59 of operation manual for size) 3.Reference diagram of wiring (Refer to p9 and after of operation manual)
The following diagram is explained about K-ECF25. But
the layout of parts is same with K-ECH45.
*1 配線工事・各種調整等に際しては取扱説明書を必ず読んでください。間違えると故障・
事故の可能性があります。
*2 リモート端子を使用しない場合は、接点の代わりにジャンパ線を接続してください。
*3 24Vと0V端子はそれぞれ内部で全て接続されています。
*4 電流制限器:入力回路に流れる電流も含めた合計値が200mAに近付くと電圧降下を始めます。
緑/黄
AC100~115V
/200~230V
50/60Hz
アース
パーツフィーダ
N
ECG25/ECJ45接続図
L
1
2
外部制御信号
ヒューズ ECG25:3A
ECJ45:5A
+V
アースバー
アースバーへ
※アース線の色は緑
または黒の場合も
あります。
SOL(DC24V)
MAX 200mA
センサ1
青
茶
黒
センサ2
青
茶
黒
速度切替え
信号入力
アナログ入力
(速度指令)
MAX 5V
緑/黄
EM
C2
C1
AL1
Y1C
Y1A
CR1
CR2
異常信号出力
警報信号出力
運転中信号出力
コントローラ内部
24V
X1
0V
A1
B2
B1
IN2
IN1
P0
24V
0V
0V
0V
24V
P1
24V
P2
24V
SOL(DC24V)
SOL(DC24V)
ジャンパ線
接点orTr
0V
24V
3.3k
3.3k
3.3k
3.3k
3.3k
10k
CPUへ
*3
*2
*3
*4
24V
電源
ヒューズ
DC24V
振動センサ用
コネクタ
1P
2P
3P
Before use
This manual is a simplified version on precautions,
operating method etc. for use of this machine.
Refer to separate operation manual for the actual
use.
This manual is applicable to Version 02.0
onward. Please use after confirming information
displayed immediately after the power supply is
turned ON.
№PMPC036E-c
K-ECG25
V.F. CONTROLLER JAPAN
AC100-115/200-230V 50/60Hz 2A
FUNC
RESET
DATA
ENTER
STOP
JOG
RUN
l
0
RoHS
Vib.ARUN
Fre.A
LIMIT
Speed control knob
Operation panel
Warning seal
Power switch
Rubber bush
Cable ground
Production No. (Ser. No.)
Data display
Lamp for operation
ECG25/ECJ45 connection diagram
*1 Read the operation manual in doing wiring construction and other various adjustments.
Error may cause failure and accident.
*2 Space between X1-0V terminals are short-circuited at the time of shipment.
When you do not use a remote terminal, connect a jumper wire instead of contact.
*3 Terminals 24V and 0V are all connected in the inside.
*4 Current limiter: When total figure including current in input circuit comes close to 200mA,
voltage starts to drop.
26
5
13
ケーブル
2-φ3.5
4
P1398
NTN
15
18
10
Note the installation
direction !
Cable
Driving signal
Warning signal output
bnormal signal output
Parts feede
To earth ba
Green /yellow
Earth
Green
/yellow
*Color of earth wire
is green or black
Fuse
ECF25: 3A
ECH45: 5A
Inside of controller
Jumper wire
*2
External control signal
Contact point or Tr
Sensor 1
Sensor 2
Speed switching
signal input
nalog input
(Speed instruction)
Connector for
vibration sensor
Brown
Blue
Blue
Black
Brown
Earth bar
To CPU
Black
Fuse