IMPORTANT NOTE
Simulated coals, or simulated logs, together with
simulated black bark, are supplied with this
appliance. These are all manufactured from
refractory fibre. Do not use real coals, logs or bark,
as this is dangerous. If the simulated coals, simulated
logs or simulated black bark need renewing please
obtain suitable replacements from your stockist.
USE & MAINTENANCE INSTRUCTIONS
FOR CHESNEYS ALCHEMY EVOLUTION PLUS GAS FIRES
(NATURAL GAS ONLY)
FOR DECORATIVE PURPOSES ONLY
NATURAL GAS MODELS: N2, N2I, N3R, N3I, N5R & N5
GENERAL
a. This fire must be installed by a properly qualified (in accordance with National & Local Regulations) Installation Engineer.
b. The connection of this appliance, and ventilation requirements (if any) are to be according to National & Local Codes.
c. The chimney should be swept before the appliance is installed.
d. Open fires are a hazard; it is recommended that a guard be fitted to provide protection for children, the elderly or infirm. (See
National & Local Regulations if any.)
e. This appliance is intended for decorative purposes only.
f. Do not throw rubbish on, or attempt to burn any materials on this appliance. Any debris or foreign matter must be removed
from the fire.
g. The appliance should be serviced by a qualified gas fitter every 12 months.
LIGHTING & CONTROLLING THE FIRE MANUAL FIRE
FOR A FIRE WITH THERMATRONIC ELECTRONIC CONTROL SYSTEM SEE SEPARATE OPERATING INSTRUCTIONS
a. Turning pilot on from off position depress knob and turn anti-clockwise until it sparks.
More than one attempt may be required to light the pilot. Once lit hold in for about 10
seconds.
Release knob and turn to pilot position.
b. To turn burner on from pilot position depress knob and turn anti-clockwise to low flame.
To go to high flame depress knob again and turn anti-clockwise as far as it will go.
The flame can be varied to any point between high and low as desired.
c. To turn off depress knob and turn clockwise depressing knob at each point as you go
all the way round to off.
IMPORTANT NOTES
d. This appliance is fitted with an oxygen depletion sensing system, which automatically shuts off the gas supply to the main
burner if the oxygen level in the room is depleted, due to a lack of primary air, or obstructed flue that would lead to incomplete
combustion of the gas.
e. In the event that the fire shuts down due to any reason, attempt to restart it. If there is a continuing problem call in a properly
qualified specialist engineer.
f. There are no user replaceable parts in this appliance.
g. Do not change the fire front or fret supplied without checking with the supplier of this unit. A minimum primary air
inlet area of 50 sq. cm is required for the safe and efficient operation of the fire. Failure to observe this instruction is
potentially dangerous and will possibly invalidate the guarantee.
h. Regularly inspect the purpose provided ventilator (if fitted) to check that it is free from any obstruction.
i. The chimney should be regularly checked to ensure that all the products of combustion are entering the flue & that there is no
build-up of soot. If there is, the appliance must be cleaned.
CLEANING THE FIRE
a. Do not use a vacuum cleaner to clean the appliance as you will suck up the vermiculite.
b. Gently remove the Embaglow material & fuel effect pieces one by one. Remove soot deposits with a soft brush.
c. The vermiculite granules should be level with the top edge of the burner tray. Top up the vermiculite granules if
required. Ensure that vermiculite granules are not obstructing the burner slots or fouling the pilot burner assembly.
d. Re-lay the fuel effect as shown on the relevant drawing. Do not add more simulated coals, logs or black bark pieces
or change the firebed layout in anyway.
CHESNEYS
ALCHEMY EVOLUTION PLUS GAS FIRE
by
Unit 4, Kimpton Trade & Business Centre
Minden Road, Sutton, Surrey SM3 9PF
Tel: 020 8254 6802
Question and Answer IconNeed help?

Do you have a question about the Nu-Flame CHESNEYS ALCHEMY EVOLUTION PLUS N2 and is the answer not in the manual?

Nu-Flame CHESNEYS ALCHEMY EVOLUTION PLUS N2 Specifications

General IconGeneral
BrandNu-Flame
ModelCHESNEYS ALCHEMY EVOLUTION PLUS N2
CategoryIndoor Fireplace
LanguageEnglish

Summary

Use & Maintenance Instructions

GENERAL

General safety, installation, and usage guidelines for the gas fire appliance.

LIGHTING & CONTROLLING THE FIRE – MANUAL FIRE

Step-by-step instructions for lighting and adjusting the flame on manual control models.

CLEANING THE FIRE

Procedures for safely cleaning the gas fire, including fuel effect and vermiculite.

Installation & Servicing Instructions

APPLIANCE DATA

Key technical specifications and model details for the gas fire appliance.

FLUE REQUIREMENTS

Essential guidelines for ensuring proper flue installation and performance for safe operation.

VENTILATION

Requirements for adequate room ventilation according to national and local codes.

APPLIANCE LOCATION

Recommended placement and siting considerations for the gas fire appliance.

INSTALLATION OF THE APPLIANCE

Detailed steps for correctly installing the gas fire, including connections and safety checks.

ARRANGEMENT OF FUEL EFFECT

Guidance on positioning logs, coals, and Embaglow for optimal aesthetic and performance.

TIPS - PLEASE READ BEFORE PROCEEDING TO THE RELEVENT LOG OR COAL LAYOUT

Important tips for arranging fuel effect to ensure proper airflow and prevent sooting.

COMMISSIONING THE FIRE

Steps for initial setup, testing for spillage, and initial burning of the appliance.

SPECIAL NOTES

Important remarks on servicing, initial smells, safety guards, and cleaning precautions.

FAULT FINDING GUIDE. SYMPTOMS AND POSSIBLE CAUSES

Troubleshooting common issues like no spark, pilot light problems, and flame appearance.

SERVICING INSTRUCTIONS

Step-by-step guide for performing regular maintenance and servicing on the gas fire.

Nu-Flame Warranty and Repair Procedure

Details on warranty coverage, repair process, and contact information for technical support.

Related product manuals