Unit 4, Kimpton Trade & Business Centre
Minden Road, Sutton, Surrey SM3 9PF
Tel: 020 8254 6802
USE & MAINTENANCE INSTRUCTIONS
FOR NU-FLAME EVOLUTION PLUS GAS EFFECT FIRES
(NATURAL GAS & LPG)
FOR DECORATIVE PURPOSES ONLY
NATURAL GAS MODELS: N1, N1I, N2R, N2, N2I, N3R, N3, N3I, N4R, N4, N4I, N5R, N5, N5I & N6
LPG MODELS: L1, L2R, L2, L3R, L3, L4R, L4 , L5 & L6
GENERAL
a. This fire must be installed by a properly qualified (in accordance with National & Local Regulations) Installation Engineer.
b. The connection of this appliance, and ventilation requirements (if any) are to be according to National & Local Codes.
c. The chimney should be swept before the appliance is installed.
d. Open fires are a hazard; it is recommended that a guard be fitted to provide protection for children, the elderly or infirm. (See
National & Local Regulations if any.)
e. This appliance is intended for decorative purposes only.
f. Do not throw rubbish on, or attempt to burn any materials on this appliance. Any debris or foreign matter must be removed
from the fire.
g. The appliance should be serviced by a qualified gas fitter every 12 months.
LIGHTING & CONTROLLING THE FIRE – MANUAL FIRE
FOR A FIRE WITH THERMATRONIC ELECTRONIC CONTROL SYSTEM SEE SEPARATE OPERATING INSTRUCTIONS
a. Turning pilot on from off position depress knob and turn anti-clockwise until it sparks.
More than one attempt may be required to light the pilot. Once lit hold in for about 10 seconds.
Release knob and turn to pilot position.
b. To turn burner on from pilot position depress knob and turn anti-clockwise to low flame.
To go to high flame depress knob again and turn anti-clockwise as far as it will go.
The flame can be varied to any point between high and low as desired.
c. To turn off depress knob and turn clockwise depressing knob at each point as you go
all the way round to off.
IMPORTANT NOTES
d. This appliance is fitted with an oxygen depletion sensing system, which automatically shuts off the gas supply to the main
burner if the oxygen level in the room is depleted, due to a lack of primary air, or obstructed flue that would lead to incomplete
combustion of the gas.
e. In the event that the fire shuts down due to any reason, attempt to restart it. If there is a continuing problem call in a properly
qualified specialist engineer.
f. There are no user replaceable parts in this appliance.
g. Do not change the fire front or fret supplied without checking with the supplier of this unit. A minimum primary air
inlet area of 50 sq. cm is required for the safe and efficient operation of the fire. Failure to observe this instruction is
potentially dangerous and will possibly invalidate the guarantee.
h. Regularly inspect the purpose provided ventilator (if fitted) to check that it is free from any obstruction.
i. The chimney should be regularly checked to ensure that all the products of combustion are entering the flue & that there is no
build up of soot. If there is, the appliance must be cleaned.
CLEANING THE FIRE
a. Do not use a vacuum cleaner to clean the appliance as you will suck up the vermiculite.
b. Gently remove the simulated coal, pebbles, logs or driftwood one by one & remove soot deposits with a soft brush.
c. The vermiculite granules should be level with the top edge of the burner tray. Top up the vermiculite granules if required.
Ensure that vermiculite granules are not obstructing the burner slots or fouling the pilot burner assembly.
d. Coal, pebble, log & driftwood effect fires: Re-lay as shown on the relevant drawing. Do not add more simulated coals,
pebbles, logs or driftwood or change the firebed layout in anyway.
IMPORTANT NOTE
Simulated coals, simulated pebbles, simulated logs,
simulated driftwood or crushed rock manufactured
from refractory fibre, are supplied with this appliance.
Do not use real coals, pebbles, logs or driftwood, as
this is dangerous. If the simulated coals, simulated
pebbles, simulated logs or simulated driftwood need
renewing please obtain suitable replacements from a
Nu-Flame stockist.
Question and Answer IconNeed help?

Do you have a question about the Nu-Flame N6 and is the answer not in the manual?

Summary

Use & Maintenance Instructions

General

General installation and usage guidelines for Nu-Flame gas effect fires.

Lighting & Controlling the Fire - Manual Fire

Step-by-step instructions for lighting and controlling the fire using manual controls.

Important Notes

Key safety and operational considerations for the appliance.

Cleaning the Fire

Procedures for cleaning the Nu-Flame gas effect fire and its components.

Installation & Servicing Instructions

Appliance Data

Technical specifications and details of the Nu-Flame Evolution Plus gas effect fire.

Flue Requirements

Guidelines and specifications for flue installation and performance.

Ventilation

Requirements and considerations for appliance ventilation and room air supply.

Appliance Location

Recommended placement and positioning of the appliance.

Installation of the Appliance

Step-by-step guide for installing the Nu-Flame gas effect fire.

Arrangement of Fuel Effect

Instructions for arranging simulated coals, pebbles, logs, or driftwood for aesthetic effect.

Layout for Simulated Coals

Detailed guide on arranging simulated coals for optimal appearance and function.

Layout for Simulated Pebbles

Detailed guide on arranging simulated pebbles for optimal appearance and function.

Layout for Simulated Logs; Driftwood

Detailed guide on arranging simulated logs or driftwood for optimal appearance and function.

Lighting & Controlling the Fire - Manual Fire

Step-by-step instructions for lighting and controlling the fire using manual controls.

Commissioning the Fire

Procedures for initial setup, testing, and safe operation verification.

Fault Finding Guide. Symptoms and Possible Causes

Troubleshooting guide for common issues encountered with the appliance.

Servicing Instructions

Detailed steps for performing regular maintenance and servicing on the appliance.

Nu-Flame Warranty and Repair Procedure

Chargeable repairs during and after the warranty period

Information on costs and procedures for repairs outside the standard warranty.

Nu-Flame N6 Specifications

General IconGeneral
BrandNu-Flame
ModelN6
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals