GENERAL
a. This fire must be installed by a properly qualified (in accordance with National & Local Regulations) Installation Engineer.
b. The connection of this appliance, and ventilation requirements (if any) are to be according to National & Local Codes.
c. The chimney should be swept before the appliance is installed.
d. Open fires are a hazard; it is recommended that a guard be fitted to provide protection for children, the elderly or infirm. (See
National & Local Regulations if any.)
e. This appliance is intended for decorative purposes only.
f. Do not throw rubbish on, or attempt to burn any materials on this appliance. Any debris or foreign matter must be removed
from the fire.
g. The appliance should be serviced by a qualified gas fitter every 12 months.
LIGHTING & CONTROLLING THE FIRE – MANUAL FIRE
FOR A FIRE WITH THERMATRONIC ELECTRONIC CONTROL SYSTEM SEE SEPARATE OPERATING INSTRUCTIONS
a. Turning pilot on from off position depress knob and turn anti-clockwise until it sparks.
More than one attempt may be required to light the pilot. Once lit hold in for about 10 seconds.
Release knob and turn to pilot position.
b. To turn burner on from pilot position depress knob and turn anti-clockwise to low flame.
To go to high flame depress knob again and turn anti-clockwise as far as it will go.
The flame can be varied to any point between high and low as desired.
c. To turn off depress knob and turn clockwise depressing knob at each point as you go
all the way round to off.
IMPORTANT NOTES
d. This appliance is fitted with an oxygen depletion sensing system, which automatically shuts off the gas supply to the main
burner if the oxygen level in the room is depleted, due to a lack of primary air, or obstructed flue that would lead to incomplete
combustion of the gas.
e. In the event that the fire shuts down due to any reason, attempt to restart it. If there is a continuing problem call in a properly
qualified specialist engineer.
f. There are no user replaceable parts in this appliance.
g. Do not change the fire front or fret supplied without checking with the supplier of this unit. A minimum primary air
inlet area of 50 sq. cm is required for the safe and efficient operation of the fire. Failure to observe this instruction is
potentially dangerous and will possibly invalidate the guarantee.
h. Regularly inspect the purpose provided ventilator (if fitted) to check that it is free from any obstruction.
i. The chimney should be regularly checked to ensure that all the products of combustion are entering the flue & that there is no
build up of soot. If there is, the appliance must be cleaned.
CLEANING THE FIRE
a. Do not use a vacuum cleaner to clean the appliance as you will suck up the vermiculite.
b. Gently remove the simulated coal, pebbles, logs or driftwood one by one & remove soot deposits with a soft brush.
c. The vermiculite granules should be level with the top edge of the burner tray. Top up the vermiculite granules if required.
Ensure that vermiculite granules are not obstructing the burner slots or fouling the pilot burner assembly.
d. Coal, pebble, log & driftwood effect fires: Re-lay as shown on the relevant drawing. Do not add more simulated coals,
pebbles, logs or driftwood or change the firebed layout in anyway.
IMPORTANT NOTE
Simulated coals, simulated pebbles, simulated logs,
simulated driftwood or crushed rock manufactured
from refractory fibre, are supplied with this appliance.
Do not use real coals, pebbles, logs or driftwood, as
this is dangerous. If the simulated coals, simulated
pebbles, simulated logs or simulated driftwood need
renewing please obtain suitable replacements from a
Nu-Flame stockist.
Question and Answer IconNeed help?

Do you have a question about the Nu-Flame N3R and is the answer not in the manual?

Summary

Product Overview and Operation

Important Notes and General Guidelines

Covers initial warnings, general safety, and operational notes for the fire.

Manual Fire Lighting and Control

Instructions for lighting and controlling the manual gas effect fire.

Cleaning the Fire

Step-by-step guide for cleaning the gas effect fire and its components.

Installation and Technical Data

User Record Keeping Section

Section for users to record purchase, installation, and serial number details.

Appliance Technical Specifications

Provides key technical specifications for the Nu-Flame Evolution Plus gas effect fire.

Model Specifications (Natural Gas & LPG)

Details of Nu-Flame natural gas and LPG models, including flue classes, gas type, and pressure.

Flue and Hearth Installation Requirements

Essential requirements for flue and hearth installation to ensure safe operation.

Installation Procedures and Fuel Effect Layouts

Appliance Location Guidelines

Guidelines for selecting the correct and safe location for the gas effect fire.

Detailed Installation Steps

Detailed steps for installing the appliance, including gas connections and safety checks.

Fuel Effect Arrangement Guidance

General guidance on arranging simulated coals, pebbles, logs, or driftwood for best appearance.

Layout for Simulated Coals

Detailed instructions and diagrams for laying out simulated coals in layers.

Layout for Simulated Pebbles

Detailed instructions and diagrams for laying out simulated pebbles in layers.

Layout for Simulated Logs;Driftwood

Detailed instructions and diagrams for laying out simulated logs or driftwood.

Commissioning, Servicing, and Troubleshooting

Commissioning the Fire

Procedures for commissioning the fire, including spillage testing and initial burn-in.

Troubleshooting Common Faults

Guide to diagnose and resolve common faults with the gas effect fire.

Servicing and Special Operational Notes

Instructions for routine servicing and important operational notes.

Warranty and Repair Information

Nu-Flame Warranty and Repair Procedure

Details of the 1-year warranty, return procedure, and repair process.

Chargeable Repairs and After Warranty

Information on costs and procedures for repairs outside the warranty period.