MC-II Plus WP-PM Flow Analyzer
2 May 2005
The Weatherproof MC-II Plus Flow Analyzer allows for use in outdoor locations,
provides excellent protection from the elements, and offers a convenient means of
mounting directly to the turbine meter. A remote mount version is also available.
Specifications
Enclosure
Panel Mount
¼ Square DIN mounting MC-II Plus Flow Analyzer
or
Rack mounting front panel 8.75” H x 5.79” W
with one MC-II Plus Flow Analyzer
or
Rack mounting front panel 8.75” H x 5.79” W
with two MC-II Plus Flow Analyzers
Weatherproof
Direct mount – fiberglass, mounts directly on meter
Or
Remote mount – fiberglass, mounts on pole or bulkhead
System Power Internal Power Supply - 3.6 VDC, D-size lithium battery
External power supply (8 to 30 VDC) with internal battery backup
(reverse polarity protected)
Loop powered (4-20 mA) with internal battery backup
(reverse polarity protected)
Loop Burden: 8 VDC
Maximum voltage: 30 VDC
Load resistance: 1100 ohms @ 30 VDC
250 ohms @ 13 VDC
Operating Temperature
-40°C to 75°C (-40°F to 167°F)
LCD: -30°C to 75°C (-22°F to 167°F)
LCD Display Simultaneous display of 7-digit volume, 6-digit rate, 0.3” character
height
Displays units of measurement
BBL, GAL, MCF and M³ for volume
BPD, GPM, MCF/D and M³/D for flow rate
Updates every 2 seconds
Keypad 4-key membrane switch
Inputs Pulse input from flow meter, 15 to 3500 Hz, 20 mV to 10 V, input
sensitivity keypad configurable from 20 mVP-P to 120 mVP-P
Remote volume reset, optically isolated (bi-directional) input, 3–30
VDC supply range, contact duration 25 mS