DC INVERTER HEAT PUMP
Installation And Operation Instruction
Question and Answer IconNeed help?

Do you have a question about the Nulite NE-C3BZ-B2F and is the answer not in the manual?

Summary

Introduction and Manual Overview

Product Features

Technical Specifications: Parameters

Lists technical parameters including model, size, weight, and power source for the heat pump.

Product Dimensions and Drawings

Presents diagrams illustrating the physical dimensions of various heat pump models.

Installation Procedures

General Operating Instructions

Outlines key safety warnings and general operational guidelines for using the heat pump.

Heat Pump Installation Guidelines

Details guidelines for installing the heat pump unit, including location and infrastructure requirements.

Operational Safety Warnings

Highlights important safety warnings to prevent injury or unit malfunction during operation.

Electrical Circuit Connection

Provides detailed instructions and considerations for electrical wiring and connections to the unit.

Trial Running and Checks

Describes the procedures and essential checks for performing trial runs after the unit has been installed.

Maintenance and Repair Guide

Maintenance and Cleaning Procedures

Details procedures for routine maintenance, including external cleaning, waterway descaling, and evaporator cleaning.

Troubleshooting Common Issues

Offers solutions for common problems encountered, such as the unit not working or producing abnormal sounds.

Error Codes and Fault Diagnosis

Lists various error codes displayed by the unit and provides guidance for fault diagnosis.

Electrical Wiring Diagrams

Overview

This document provides installation and operation instructions for a DC Inverter Heat Pump, designed for heating and cooling applications. It covers various models including NE-C3BZ-B2F, NE-C5BZ-B2F, NE-C6BZ-B2F, NE-C8BZ-B2IIF, and NE-C10BZ-B2IIF.

Function Description

The DC Inverter Heat Pump is a versatile unit capable of providing both heating and cooling, as well as hot water. It operates as a heat pump water heater, utilizing inverter technology for efficient energy use. The system is designed to circulate water, which can be used for various purposes such as domestic hot water or floor heating. The unit extracts heat from the ambient air and transfers it to the water, or vice versa for cooling, making it an energy-efficient solution for climate control and water heating.

Important Technical Specifications

The manual details several technical parameters for different models:

General Specifications:

  • Ring Temperature Working Range: -25°C to 43°C
  • Water Temperature Working Range: 7°C to 60°C
  • Water Pressure Working Range: ≤0.45 MPa
  • Refrigerant: R410A (weights vary by model)
  • Control Panel Fuse Wire: T6.3AL/250V
  • Water Pipe Diameter: G3/4" (inner) for NE-C3BZ-B2F, G1" (inner) for NE-C5BZ-B2F and NE-C6BZ-B2F, G1-1/2" (inner) for NE-C8BZ-B2IIF and NE-C10BZ-B2IIF.

Model-Specific Parameters:

NE-C3BZ-B2F:

  • Size (LWH mm): 1119340912
  • Net Weight (KG): 100
  • Power Source: 220V~50Hz
  • Rated Cooling Capacity (W): 7500
  • Rated Refrigerating Input Power / Current (A): 2560W / 11.6A
  • Rated Hot Water Heating Capacity (W): 8450
  • Rated Heating Input Power / Current (A): 2500W / 11.4A
  • Rated Floor Heating Capacity (W): 5390
  • Rated Heating Input Power / Current (A) (Floor Heating): 2300W / 10.5A
  • Maximum Input Power / Current (A): 3250W / 14.8A
  • Refrigerant / Weight: R410A / 2200g
  • Rated Water Flow (m³/h): 1.29

NE-C5BZ-B2F:

  • Size (LWH mm): 11193471249
  • Net Weight (KG): 135
  • Power Source: 220V~50Hz
  • Rated Cooling Capacity (W): 12500
  • Rated Refrigerating Input Power / Current (A): 4300W / 19.5A
  • Rated Hot Water Heating Capacity (W): 14000
  • Rated Heating Input Power / Current (A): 4180W / 19.0A
  • Rated Floor Heating Capacity (W): 9300
  • Rated Heating Input Power / Current (A) (Floor Heating): 4130W / 18.4A
  • Maximum Input Power / Current (A): 5400W / 24.5A
  • Refrigerant / Weight: R410A / 3000g
  • Rated Water Flow (m³/h): 2.15

NE-C6BZ-B2F:

  • Size (LWH mm): 11193471249
  • Net Weight (KG): 138
  • Power Source: 220V~50Hz
  • Rated Cooling Capacity (W): 15000
  • Rated Refrigerating Input Power / Current (A): 5260W / 23.8A
  • Rated Hot Water Heating Capacity (W): 16800
  • Rated Heating Input Power / Current (A): 5060W / 23.2A
  • Rated Floor Heating Capacity (W): 10770
  • Rated Heating Input Power / Current (A) (Floor Heating): 4780W / 21.7A
  • Maximum Input Power / Current (A): 6500W / 29.5A
  • Refrigerant / Weight: R410A / 3300g
  • Rated Water Flow (m³/h): 2.58

NE-C8BZ-B2IIF:

  • Size (LWH mm): 12115681496
  • Net Weight (KG): 155
  • Power Source: 220V~50Hz (for cooling) / 380V 3N~ 50Hz (for heating)
  • Rated Cooling Capacity (W): 20000
  • Rated Refrigerating Input Power / Current (A): 7140W / 32.5A (220V) or 7140W / 12.7A (380V)
  • Rated Heating Capacity (W): 22500
  • Rated Heating Input Power / Current (A): 7030W / 31.5A (220V) or 7030W / 12.5A (380V)
  • Rated Hot Water Heating Capacity (W): 14500
  • Rated Floor Heating Input Power / Current (A): 6500W / 29.5A (220V) or 6500W / 11.5A (380V)
  • Maximum Input Power / Current (A): 9280W / 42.2A (220V) or 9280W / 16.6A (380V)
  • Refrigerant / Weight: R410A / 4800g
  • Rated Water Flow (m³/h): 3.44

NE-C10BZ-B2IIF:

  • Size (LWH mm): 12115681496
  • Net Weight (KG): 165
  • Power Source: 380V 3N~ 50Hz
  • Rated Cooling Capacity (W): 25000
  • Rated Refrigerating Input Power / Current (A): 8920W / 15.9A
  • Rated Heating Capacity (W): 28100
  • Rated Heating Input Power / Current (A): 8460W / 15.1A
  • Rated Hot Water Heating Capacity (W): 18600
  • Rated Floor Heating Input Power / Current (A): 8340W / 14.9A
  • Maximum Input Power / Current (A): 12030W / 21.5A
  • Refrigerant / Weight: R410A / 5000g
  • Rated Water Flow (m³/h): 4.3

Usage Features

The heat pump is designed for user convenience and safety, with several key usage features:

  • Control Panel: The unit features a control panel for operation, displaying time, setting temperature, and current temperature. Both DH and HT panel types are shown, with buttons for On/Off, Mode selection (Heating, Cooling, Defrosting), Timer Setting, Up/Down parameter adjustment, and Lock.
  • Operating Modes: Users can select between heating, cooling, and defrosting modes.
  • Temperature Adjustment: The water temperature can be adjusted to a comfortable level, with a recommended range of 38~42°C for showering. The maximum water temperature is 55°C.
  • Safety Precautions: The manual emphasizes several safety features and warnings:
    • Professional installation is mandatory.
    • Proper grounding is essential and altering the grounding method is forbidden.
    • The unit must be filled with water before operation.
    • All water system valves must be open during operation.
    • A removable filter must be installed at the water inlet and cleaned periodically.
    • The unit should not be installed in places with combustible gas leaks.
    • Hands or foreign objects should not be inserted into the air outlet.
    • In winter, if the unit is powered off or not in use for a long time, all water must be discharged to prevent freezing and cracking of the heat exchanger or water pipes.
    • The control panel should not be installed in a bathroom to avoid moisture damage.
    • The power connection must include an all-pole disconnect device and leakage protection device with at least 3mm contact distance.
    • Damaged power cords must be replaced by a professional.
    • The unit's water quality must meet national standards for domestic water consumption.
  • Energy Saving: For optimal energy efficiency, the unit should be installed in a well-ventilated area.
  • Trial Running: A detailed trial running procedure is outlined, including checks for correct installation, power supply, piping, wiring, ventilation, water drainage, leakage protection, thermal insulation, and grounding. It also involves checking the current, function keys, indicator lights, water leakage in the circulating system, condensed water discharge, and system pressure.

Maintenance Features

Regular maintenance is crucial for the longevity and efficient operation of the heat pump:

  • External Cleaning: The unit should be turned off and wiped with a damp cloth and a small amount of neutral detergent. Abrasive cleaners like gasoline or acidic solutions are prohibited.
  • Waterway Cleaning: The waterway should be emptied every 3 months. Descaling can be done using organic acids such as formic acid, citric acid, or acetic acid.
  • Evaporator Cleaning: The evaporator fins can be cleaned with a hard nylon brush, followed by a vacuum cleaner. Compressed air can also be used for cleaning the fin heat exchanger.
  • Filter Maintenance: The removable filter at the water inlet needs periodic cleaning (every 2 or 3 months, depending on local water quality).
  • Error Information Code: The manual provides a list of error codes (e.g., E01, E02, E03, E04, E05, E06, E07, E08, E10, E11, E12, E13, E14, E18, E21, E25, E31, E32, E33, E41, E45, E46, E48, E49) to help diagnose potential faults. If an error code appears, users are instructed to turn off the power, wait 10 seconds, and then restart. If the code persists, professional assistance is required.
  • Professional Maintenance: The maintenance of the machine must be carried out by professional personnel.

Nulite NE-C3BZ-B2F Specifications

General IconGeneral
Model NumberNE-C3BZ-B2F
RefrigerantR410A
Heating Capacity36000 BTU/h
Cooling Capacity11.0 kW
Weight (Indoor Unit)18 kg