Page 1
ALLURE
®
WS3 SERIES
RANGE HOOD
Register your product online at: www.nutone.ca/register
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society of Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. To reduce the risk of fire or electric shock, do not use this range
hood with an additional speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking
flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size
of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent
steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
ALLURE
®
WS3 SERIES RANGE HOOD
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with
the homeowner.
Homeowner: Operating and
Cleaning information on page 6.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. For best capture of cooking impurities, your range hood should
be mounted so that the top of the hood is 24-30” above the
cooking surface.
5. Please read specification label on product for further information
and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
“PREPARE HOOD LOCATION”
Run ductwork from roof or wall cap, and electrical wiring from
service panel - to installation location
“PREPARE THE HOOD”
Get your hood ready for installation
“CONNECT WIRING”
Make electrical wiring connections to hood
“INSTALL HOOD”
Secure hood to cabinet and ductwork - install bulbs and filters
“OPERATION”
How to use the hood controls
“CLEANING”
Keep your hood in top working condition
“SERVICE PARTS”
Part numbers and exploded view of hood components
“WARRANTY”
One-year limited warranty and how to contact us
NOTE If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
Patent No.:
US D450, 829 S
!
FOR DOMESTIC COOKING ONLY
!

Other manuals for NuTone ALLURE WS3 Series

Question and Answer IconNeed help?

Do you have a question about the NuTone ALLURE WS3 Series and is the answer not in the manual?

NuTone ALLURE WS3 Series Specifications

General IconGeneral
BrandNuTone
ModelALLURE WS3 Series
CategoryVentilation Hood
LanguageEnglish

Summary

General Safety and Installation Precautions

Risk of Fire, Electric Shock, and Injury

Essential safety warnings to reduce risks during operation and installation.

Cautions for Proper Use

Important cautions regarding ventilation, motor protection, and mounting height.

Installer and Homeowner Guidance

Instructions for installers and homeowners regarding manual retention and operation.

Prepare Hood Location for Installation

Ducting Options and Site Preparation

Determine duct discharge type (vertical/horizontal) and route ductwork.

Cabinet Cutout and Wiring Access

Details placement of ductwork and electrical cutout in cabinets or walls.

Prepare the Hood: Initial Steps

Filter and Bottom Cover Removal

Remove filters and the Teflon-coated bottom cover for access.

Damper/Duct Connector Handling

Remove and set aside the damper/duct connector.

Prepare the Hood: Internal Adjustments

Air Chute and Baffle Modification

Remove and re-install air chute and baffle for proper airflow.

Light Panel and Wiring Disconnection

Remove light panel and disconnect wire harness.

Prepare the Hood: Ducting and Non-Ducted

Non-Ducted Performance Ring Installation

Attach a performance ring to the blower wheel for non-ducted operation.

Duct Knockout Removal

Remove appropriate rectangular duct knockouts for installation.

Damper/Duct Connector Attachment

Attach the damper/duct connector to the hood opening.

Connect Wiring and Install Hood

Electrical Wiring Connections

Connect house wiring to the hood, ensuring proper grounding.

Hood Mounting and Securing

Hang hood using mounting screws and secure it to the cabinet.

Ductwork Connection and Bulb Installation

Connect ductwork, install bulbs, and replace bottom cover.

Operation and Cleaning

Non-Ducted Filter Usage

Guidance on using non-ducted filters for optimal performance.

Control Panel Operation

Explanation of fan speeds, light controls, delay, and filter indicator.

Heat Sentry System

Details the automatic fan adjustment based on temperature.

Cleaning and Maintenance

Instructions for cleaning aluminum mesh and charcoal filters and hood surfaces.

Service Parts Identification

Parts List with Key Numbers

Comprehensive list of replacement parts with part numbers and key identifiers.

Exploded View Diagram

Visual representation of hood components with corresponding part numbers.

Warranty Information

One Year Limited Warranty Details

Outlines the terms, coverage, and limitations of the product warranty.

Warranty Service Procedure

Steps required to obtain warranty service, including contact information.

Related product manuals