EasyManua.ls Logo

NuTone HEAT-A-VENTLITE 9965 User Manual

NuTone HEAT-A-VENTLITE 9965
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
Heat-A-Ventlite
®
(with Night Light)
MODEL: 9965
FOR BEST RESULTS
In a new construction site, install the housing (complete
with heater and ventilator) during rough-in construction of the
building. The light assembly and the grille should be installed
when the finished ceiling is in place.
Installation in an existing, finished building requires an
accessible area (attic or crawl space) above the planned
location. See “INSTALLATION IN EXISTING
CONSTRUCTION.
Do not install closer than 12 inches to a vertical surface.
Do not install over tub or shower enclosure.
UNIT DIMENSIONS
Refer to Figure 1 for housing's dimensions.
NOTE: If there will be a finished second floor above,
the Model 9965 housing requires a minimum of 2" x 8"
joist construction for mounting.
WIRING AND DUCTWORK
1. Run the required wiring during rough-in stage of
construction.
2. Total connected load: 1730 watts.
3. Plan to run 120vAC, 60 Hz wiring (with ground) on a
separate 20 Amp circuit from a power source, through
the provided wall switch, to the housing's junction box.
See wiring diagram.
4. Use 4" round duct.
INSTALLATION IN
NEW CONSTRUCTION
PREPARATION
1. Install hanger bar brackets in slots in housing. (See Fig. 3)
Do not tighten completely to allow bars to be inserted.
2. Refer to Figure 2. Insert hanger bars into brackets.
3. Refer to Figure 3. Slide hanger bar brackets down to end
of slot closest to outside edge of housing. Tighten brackets
in this position.
4. Refer to Figure 4. Remove junction box cover by
removing one screw.
5. Refer to Figure 4. Remove appropriate wiring knockout(s)
and install approved box connector(s).
FIGURE 1
FIGURE 2
FIGURE 3 FIGURE 4
7
3
4
"
14"
HANGER BARS
ADJUSTMENT
SLOT
JUNCTION
BOX
COVER
KNOCKOUTS
9
3
4
"
Question and Answer IconNeed help?

Do you have a question about the NuTone HEAT-A-VENTLITE 9965 and is the answer not in the manual?

NuTone HEAT-A-VENTLITE 9965 Specifications

General IconGeneral
CFM70 CFM
Sone Rating4.0 Sones
Bulb TypeIncandescent
Voltage120V
Noise Level4.0 Sones
Housing MaterialGalvanized Steel
Mounting TypeCeiling Mount
Blade MaterialPlastic
TypeHeater/Fan/Light
Wattage1500W Heater
Bulb Wattage100W
FunctionHeating, Ventilation, Lighting

Summary

For Best Results

Unit Dimensions

Wiring and Ductwork

Installation in New Construction

Preparation for New Construction Installation

Steps for preparing the unit for installation in new construction.

Mounting the Housing

Installing the Ductwork

Installing the Switch

Installing and Connecting the Wiring

Mounting the Grille Assembly

Installation in Existing Construction

Planning for Existing Construction Installation

Review new construction steps and check area for ducting and wiring.

Installation Steps for Existing Construction

Steps for mounting housing, connecting duct, wiring, and grille in existing construction.

NuTone One Year Limited Warranty

Parts List

Related product manuals