EasyManua.ls Logo

NuTone ISA-445 Series

NuTone ISA-445 Series
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
READ & SAVE THESE INSTRUCTIONS!
INSTALLATION INSTRUCTIONS
5˝ Inside Speaker
MODEL: ISA-445 Series
For use with the IMA4406, IM4406, IMA4006 & IM4006 Series Radio/Intercom Systems
ROUGH-IN FRAME MOUNTING
The ISA-445 5˝ speaker is mounted to the IR-50 rough-in
frame or surface mounted with IA-60.
NEW CONSTRUCTION
The IR-50 frame is mounted to a wall stud during
rough-in construction. The IW-6 wiring is also run during
rough-in construction. The speaker is mounted to the frame
once the finished wall is in place. See IR-50 Installation
Instructions.
EXISTING CONSTRUCTION
The IR-50 frame requires a cutout in the finished wall.
The frame may be mounted either directly to a wall stud or
between wall studs. The wiring is installed through the existing
walls. See IR-50 Installation Instructions.
WIRING CONNECTIONS
Refer to Figure 1. As illustrated, connect wires from the
master unit to the six (6) screw terminals. Red wire to the
terminal marked red, red/white to the terminal marked
re/white, etc.
MOUNTING
1. Refer to Figure 2. Carefully place wires inside wall.
2. Using two mounting holes in the speaker body, secure the
speaker to the frame with two (2) provided screws.
Refer to System’s Operator’s Manual for operating
instructions and warranty information. If Operator’s
Manual has been misplaced, write to: NuTone, 4820 Red
Bank Road, Cincinnati, Ohio 45227. Attention: Department
of National Field Service.
IMPORTANT – WHEN NUTONE MODEL IW-6R WIRING
IS USED:
CONNECT TO SCREWS
ON PRINTED CIRCUIT
BOARD MARKED:
ORN
BLK
BLK/WHITE
ORN/WHITE
RED
RED/WHITE
BLUE STRIP
FIGURE 2
IR-50
ISA-445
SPEAKER
IW-6
FIGURE 1
RED
RED/WHITE
BLACK
BLACK/WHITE
ORANGE/WHITE
ORANGE
Question and Answer IconNeed help?

Do you have a question about the NuTone ISA-445 Series and is the answer not in the manual?

NuTone ISA-445 Series Specifications

General IconGeneral
BrandNuTone
ModelISA-445 Series
CategorySpeakers
LanguageEnglish

Summary

Speaker Installation Procedures

Rough-in Frame Mounting

Mount the ISA-445 5" speaker to the IR-50 rough-in frame or surface mount with IA-60.

New Construction Installation

Mount IR-50 frame and run IW-6 wiring during rough-in; mount speaker after finished wall.

Existing Construction Installation

Mount IR-50 frame in finished wall and install wiring through existing walls.

Wiring Connections

Connect wires from the master unit to the six screw terminals on the speaker.

Speaker Mounting

Secure the speaker to the frame using two provided screws after placing wires inside the wall.

Important IW-6 R Wiring Note

Connect IW-6R wiring to specific marked terminals on the speaker's printed circuit board.

NuTone Two Year Limited Warranty

Warranty Coverage and Limitations

Details warranty coverage, exclusions, implied warranties, and limitations for two years.

Obtaining Warranty Service

Instructions on how to qualify for warranty service, including contact and required information.

Customer Assistance and Service

Contact information for finding service centers and obtaining technical assistance.

Related product manuals