FUSE REPLACEMENT
IF LIGHTS FAIL TO OPERATE, DISCON=
NECT POWER AT THE SERVICE EN-
TRANCE. CHECK THE FUSE AND RE-
PLACE IF NECESSARY.
DECORA1]VE
FLUE
1. Raise or remove the lower decorative flue.
2. Remove the cover from the fuse box.
3. Unscrew the cap from the fuse holder and
remove the fuse.
4. Replace the fuse with the same size and
amperage (5 x 20mm, 4 amp, 125 volt).
Do not use fuses greater than 4 amps.
Fuses greater than 4 amps may dam=
age the transformer.
5. Reinstall the fuse holder cap, fuse box
cover and flue.
6. Reconnect power at the service entrance.
FUSE
BOX
MAINTENANCE
Proper maintenance of the Range Hood will
assure proper performance of the unit.
Grease Filters
The grease filters should be cleaned fre-
quently. Use a warm detergent solution.
Grease filters are dishwasher safe.
See "INSTALL FILTERS" section for removal
and installation instructions.
ii .....................i.......................'
GREASE FILTERS
Non=Ducted Recirculation Filter
The non-ducted recirculation filter should be
changed every 6 months.
See "INSTALL FILTERS" section for removal
and installation instructions.
NON-DUCTED
RECRCULA]]ON
FILTER
-5-

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NuTone RangeMaster RM53000 Series and is the answer not in the manual?

NuTone RangeMaster RM53000 Series Specifications

General IconGeneral
BrandNuTone
ModelRangeMaster RM53000 Series
CategoryVentilation Hood
LanguageEnglish

Related product manuals