TECHNICAL SPECIFICATIONS
MODEL
NPEGG850 NPEGG2400 NPEGG3800 NPEGG5200 NPEGG6000 NPEGG7500
GENERATOR
Type Brushless, Self-energising, 2-poles, Single phase
Brushless,
Self-energising,
2-poles,
Three-phase
Voltage Regulator Condenser Type
Max. AC Output 0.85 kW 2.4kW 3.8kW 5.2kW 6.0kW 6 / 7.5 kW
Rated AC Output 0.80 kW 2.0kW 3.2kW 4.5kW 5.0kW 5 / 6.8 kW
AC Voltage 230V 230 / 400V
Frequency 50 Hz
Phase Single phase Three phase
Power Factor cos φ = 1,0
Degree of Protection IP23
Performance Class G1
Sound pressure level
(measured at 4 m.)*
Sound power level
71 db (A)
93 db (A)
72.47 db (A)
92.47 db (A)
75.55 db (A)
95.55 db (A)
74.8 db (A)
97 db (A)
75.3 db (A)
97 db (A)
ENGINE
Model 152 F UP168 UP177 UP188 UP188
Type Air-cooled 4-stroke overhead valve Petrol Engine
Stroke 52x38 mm 68x54mm 77x58mm 88x64mm 88x64mm
Displacement (cc) 80 196 270 389 389
Max. Output
(HP/RPM)
2.4/1.8
- 3600
6.5/4.9 -
3600
9/6.7 - 3600 13/9.7 - 3600 13/9.7 - 3600
Fuel Unleaded Gasoline
Fuel/Oil mix ratio - - -
Fuel tank Capacity (lt) 4.2 15 25
Rated Continuous
Operation (hs)
6 13 10 10 9 9
Lubricating oil SAE 10W - 30
Lubricating oil capacity (lt) 0.4 0.6 1.1 1.1 1.1
Starting System Recoil Starter Recoil / Electric starter
Ignition system T.C.I. Electronic starting
Spark plug type E6TC F6TC F7TC
DIMENSIONS
Lenght x Width x Height
440x320x
360 mm
590x440x
500 mm
680x510x540
mm
680x540x540
mm
Net Weight 30 kg 43 kg 67 kg 78 kg 80 kg 84 kg
Specifications subject to change without prior notice.
Generating set ISO 8528
* Measured according to EN ISO 3744 Standard.
The figures quoted are emission levels and are not necessarily
safe working levels. Whilst there is a correlation between the
emiss
ion between the emission and exposure levels this
cannot be used reliably to determine whether or not further
precautions are required.
Factors that influence the actual level of exposure of work-force
include the characteristics of the work room, the other sources
of noise etc. i.e. the number of machines and other adjacent
processes, and the length of time for which an operator is exposed
to the noise. Also the permissible exposure level can vary from
country. This information, however, will enable the user of the
machine to make a bett
er evaluation of the hazard and risk.
With Brush, Self-energising, 2-poles, Single phase
AVR
2,2 kW
2,0 kW
230 V
50 Hz
Single phase
cos φ = 1
IP 23M
G 1
168F-1
Air-cooled 4-stroke overhead valve Petrol Engine
196
6,5 / 3000
Unleaded Gasoline
15
10,6
SAE 10W - 30
0,6
Recoil Starter
T.C.I.
F6TC
620 x 450 x 480
39
65 dB(A)
95 dB (A)
68 x 54