Do you have a question about the NUTRIBULLET NB-201 and is the answer not in the manual?
Information regarding potential interactions between NutriBlast ingredients and medications.
Essential safety guidelines for operating electrical appliances safely.
Instructions to ensure proper airflow and prevent overheating of the appliance.
Tips for effectively cleaning dried-on ingredients from the NutriBullet cups.
Guidance on how to safely clean the appliance's power base unit.
Step-by-step process for blending ingredients using the NutriBullet.
Method for achieving a coarse chop or controlling extraction consistency through short bursts.
Technique to improve ingredient circulation when the mixture is too dense.
Method to dislodge stubborn ingredients clinging to the cup's sides.
Instructions for hand washing or dishwashing NutriBullet components.
Guidance on selecting and measuring leafy greens for NutriBlasts.
Recommendations for choosing and measuring fruits to create NutriBlasts.
Information on adding optional ingredients like nuts and seeds for enhanced nutrition.
The NutriBullet is a powerful blender designed to extract nutrients from fruits, vegetables, and other ingredients, creating healthy and nutritious beverages called NutriBlasts. Its primary function is to break down ingredients into a smooth, creamy consistency, making it easier for the body to absorb essential vitamins and minerals. The device is intended for home use and emphasizes a focus on maximizing the nutritional benefits of food.
To operate the NutriBullet, users first fill the NutriBullet Cup with ingredients. A crucial step is to always add liquid up to the MAX line, as blending without liquid can damage the Precision Extractor Blade. The manual recommends a 50% leafy greens and 50% fruit ratio for NutriBlasts, with optional "boosts" like nuts, seeds, or goji berries. It's important not to overfill the cup, ensuring ingredients and liquid do not exceed the MAX line. Additionally, if ice is used, it should not exceed 25% of the total blast ingredients.
Once the cup is filled, the Precision Extractor Blade is twisted onto the NutriBullet Cup and hand-tightened to ensure a sealed vessel. The cup assembly is then inverted and pressed onto the Power Base. For extraction, users press down and twist the cup onto the Power Base. The device is designed to run for no longer than 1 minute intervals. If more extraction is needed, a 1-minute wait is recommended before repeating the process, up to three times. If more than three 1-minute extractions are required, the Power Base should be allowed to cool for 2-3 minutes before continuing. This prevents overheating and potential damage to the unit.
To turn off the NutriBullet, users simply twist the cup in the opposite direction (to the right) to release the tabs and stop the blending action. Once the power base stops completely, the cup can be removed. A critical caution is highlighted regarding internal pressure: friction from the rotating blade can heat ingredients and generate pressure in the sealed vessel. If the vessel feels warm, it should be allowed to cool before carefully opening, pointed away from the body.
The NutriBullet also offers specific techniques for different blending needs. The Pulse Technique is ideal for achieving a chunky consistency, such as for salsa or coarsely chopped onions. To pulse, the user quickly presses down on the cup and immediately releases it, ensuring the machine doesn't accidentally lock on. Applying counter-clockwise pressure on the cup with one hand while tapping the top with the other helps prevent locking.
The Shake Technique is useful when ingredients are too dense or if there isn't enough liquid, causing ingredients to stick at the top of the cup. In this scenario, the cup and blade assembly are removed from the Power Base, shaken like a cocktail shaker, and then placed back on the Power Base to continue blending.
For stubborn ingredients clinging to the side of the cup, the Tap Technique can be employed. This involves taking the cup and blade assembly off the Power Base, tapping it on the counter to dislodge ingredients into the blades, and then returning it to the Power Base for further processing.
A medical warning advises individuals on certain medications (cholesterol-lowering, blood thinners, blood pressure drugs, tranquilizers, or antidepressants) to consult their doctor before consuming NutriBlast recipes. Furthermore, specific seeds and pits (apple seeds, apricot pits, cherry pits, plum pits, peach pits) are explicitly warned against due to their cyanide-releasing chemicals when ingested.
Proper maintenance is essential for the longevity and safe operation of the NutriBullet. All pieces, except the Power Base and blade holders, can be placed on the top shelf of a dishwasher or hand-washed with warm, soapy water. The Precision Extractor Blades, however, should not be washed in the dishwasher, as elevated temperatures can damage gasket seals. Instead, blades should be hand-washed immediately after each use with mild dish soap and warm (not hot) water to prevent debris from drying and sticking. A dish brush can be used to loosen debris around the blade, gaskets, and housing threads, but fingers should not be used to avoid injury from the sharp blades. The gasket ring on the Precision Extractor Blade should not be removed during washing, as this can permanently damage the blade configuration and cause leakage.
For stubborn cleanup where ingredients have dried inside the cups, the cup can be filled about two-thirds full with warm, soapy water (not hot), the Extractor Blade screwed on, and the assembly placed on the Power Base for 20-30 seconds. This helps loosen stuck ingredients, followed by a light scrub and rinse.
The Power Base itself should never be submerged in water or placed in the dishwasher. It can be cleaned by unplugging the unit and wiping down the inside and outside with a damp rag. It's crucial to ensure the Power Base is unplugged before any cleaning, assembling, disassembling, or adding parts. The coupling gear on the Power Base and blade base can become hot after use, and direct contact should be avoided.
The manual also recommends replacing the Precision Extractor Blade every 6 months or as needed for optimal performance, which can be ordered from the NutriBullet website. The NutriBullet cups and blades should never be immersed in boiling water, as this can warp the plastic and damage the gaskets.
Ventilation is important for the Power Base; it should always be operated on a level surface with unobstructed space around it to allow proper air circulation. The ventilation slots should be kept free of dust, lint, and flammable materials. The NutriBullet is not intended for use in microwave ovens, nor should any NutriBullet accessory be placed in a microwave. Heating blended mixtures should be done in microwave-safe containers or stovetop pots after transferring them out of the NutriBullet cups. Carbonated ingredients or hot liquids should never be blended, as this can cause pressure buildup and potential bursting of the container.
If the Power Base overheats, an internal thermal breaker will shut it off. In such cases, the unit should be unplugged and allowed to cool for an hour or more before attempting to use it again. The thermal breaker will reset once the unit has cooled sufficiently. The NutriBullet is not a toy and should not be played with by children.
| Power | 600 Watts |
|---|---|
| Material | Plastic |
| Blade Material | Stainless Steel |
| Wattage | 600 Watts |
| Included Components | Motor Base |