12
Remove / install heater
You can remove or install the heater to
x Retrofit your filter with a heater,
x Thoroughly clean the filter housing,
x Replace a defective heater.
Prerequisite:
x The pump is removed.
BSE0008
Troubleshooting
Malfunction Possible caus
Remed
Pump does not start up Insufficient power Check the power supply
cor
Impeller unit blocke
Cleaning
Insufficient water flow Filter housing or impeller dirty Cleaning
Impeller unit worn out Replace impeller unit
Filter media dirt
Replace filter medi
Telescopic intake blocked Clean telescopic intake
Telescopic intake and partition wall
not assembled correctl
Assemble telescopic intake
and partition wall correctl
Filtration insufficient Filter media soiled or worn Replace filter media
Filter housing clogge
Clean filter housing
Water heating insufficient
(only "Thermo" version)
Insufficient power for heater miss-
ing
Check the power supply
cord
Heater defectiv
Replac