10
The filter system with integrated UVC must be running permanently,
24 hours a day.
The UVC lamp must be replaced after 8,000 hours of operation in
order to ensure that the Filtoclear UVC continues to operate with
optimum effectiveness.
The filter system must be cleaned regularly.
Pressure loss due to height difference
The selection table allows for a maximum height difference of
3,25 feet between the surface of the water and the highest point
of the filtering system. If the height difference is greater than 3,25
feet, you should use a correspondingly more powerful pump.
English
Pressure loss due to hoses
Use large hoses if possible in order to minimise pressure loss.
Please use the following hose diameters for hoses up to 13 feet
in length:
Filtoclear 800 1 – 1¼ inches
Filtoclear 1.600 1 – 1½ inches
Filtoclear 3.000 1¼ - 1½ inches
Filtoclear 4.000 inches
1''
1 ¼''
1 ½''
¾“
Slight pollution of pond
without fish population
Heavy pollution of pond
with fish population
Aquamax Filtoclear 800 Filtoclear 1.600
1.600 SF 800 gal 400 gal 1.050 gal 525 gal
2.200 SF - - 1.600 gal 800 gal
3.000 SF - - - -
3.500 SF - - - -
Aquamax Filtoclear 3.000 Filtoclear 4.000
1.600 SF 1.600 gal 800 gal 2.100 gal 1.050 gal
2.200 SF 2.100 gal 1.050 gal 2.400 gal 1.200 gal
3.000 SF 2.640 gal 1.320 gal 3.000 gal 1.500 gal
3.500 SF 3.000 gal 1.500 gal 4.000 gal 2.000 gal