  • D
    Dominic DiazSep 23, 2025
    How to resolve Coil2 Temp. Sensor Fault on Oasis Heat Pump?
    • T
      Tyler YoungSep 23, 2025
      A 'Coil2 Temp. Sensor Fault' on your Oasis Heat Pump indicates that the temperature sensor is broken or short-circuited. You should check or replace the temperature sensor.
  • C
    christophermorrowAug 23, 2025
    Why does my Oasis Heat Pump show Flow Switch Prot.?
    • J
      James PerezAug 23, 2025
      The 'Flow Switch Prot.' error on your Oasis Heat Pump indicates there's no water or very little water in the water system. You should check the pipe water flow and the water pump to ensure they are functioning correctly.
  • N
    nicholas67Aug 25, 2025
    How to fix Communication Fault on Oasis I Series Heat Pump?
    • C
      Cindy RobbinsAug 26, 2025
      A 'Communication Fault' on your Oasis Heat Pump means there's a communication failure between the wire controller and the mainboard. To resolve this, check the wire connection between the remote wire controller and the main board to ensure it's properly connected.
  • K
    Kenneth MartinezAug 26, 2025
    What causes Ant-freezing Prot. in Oasis Heat Pump, and how to solve it?
    • R
      rscottAug 27, 2025
      The 'Ant-freezing Prot.' error in your Oasis Heat Pump system is triggered when the water flow is insufficient. Inspect the pipe water flow and check if the water system is jammed.
  • M
    Maria MercadoAug 27, 2025
    What does Low Pressure Prot. mean on Oasis I Series?
    • U
      urodriguezAug 27, 2025
      A 'Low Pressure Prot.' message on your Oasis Heat Pump indicates low pressure. You should check the pressure switch and the cold circuit.
  • T
    Tiffany WoodSep 18, 2025
    What does Antifreeze Temp. Sensor Fault mean on Oasis Heat Pump?
    • Y
      ywoodsSep 18, 2025
      An 'Antifreeze Temp. Sensor Fault' indicates that the antifreeze temperature sensor is either broken or short-circuited. You should check and replace this temperature sensor.
  • D
    dixonlisaSep 15, 2025
    How to troubleshoot Suction Temp. Sensor Fault on Oasis Heat Pump?
    • M
      Morgan MooreSep 15, 2025
      A 'Suction Temp. Sensor Fault' on your Oasis Heat Pump means the temperature sensor is broken or short circuit. To fix this, check or change the temperature sensor.
  • S
    Shannon MyersSep 16, 2025
    What causes Discharge Temp. Sensor Fault in Oasis I Series?
    • T
      twilliamsSep 16, 2025
      A 'Discharge Temp. Sensor Fault' on your Oasis Heat Pump indicates that the temperature sensor is broken or short-circuited. You should check or replace the temperature sensor.
  • A
    aliciadavilaSep 6, 2025
    What to do if Oasis I Series Heat Pump displays Pressure sensor Fault?
    • V
      Vanessa WilliamsSep 6, 2025
      If your Oasis Heat Pump is showing a 'Pressure sensor Fault', it means the pressure sensor is broken. You should check or change the pressure sensor.
  • R
    Robert CrosbySep 3, 2025
    What causes Fan Motor1 Fault in Oasis Heat Pump?
    • J
      John GreenSep 4, 2025
      A 'Fan Motor1 Fault' in your Oasis Heat Pump can be caused by: 1. The motor being in a locked-rotor state. 2. A bad wire connection between the DC-fan motor module and the fan motor. To fix this, you can try changing to a new fan motor or checking the wire connections to ensure they are secure.

Summary

Introduction to Oasis Heat Pumps

Unit Dimensions and Specifications

Quick Start Guide for Heat Pump Installation

Pre-Installation Steps

Steps for preparing the heat pump unit before connecting it to the plumbing system.

Plumbing Installation Guide

Instructions for connecting the heat pump to the pool or spa filtration plumbing.

Electrical Connection Steps

Guidance on connecting the heat pump unit to the electrical power supply.

Initial Start-Up and Commissioning

Procedure for turning on the heat pump and verifying its operation after installation.

Safety Instructions for Heat Pump Operation

Safe Transport of Refrigerant Equipment

Guidelines for the safe transport of equipment containing flammable refrigerants.

Workplace Safety Procedures for Refrigerant Handling

Area Preparation and Work Environment

Ensuring a safe work environment, including area checks, controlled procedures, and ventilation.

Refrigerant Handling and Ignition Control

Safety measures for handling refrigerants, leak detection, fire extinguishers, and ignition sources.

Refrigeration Equipment Checks

Checks related to the refrigeration equipment, including markings and component materials.

Electrical and Component Safety Precautions

Electrical Device and Cabling Safety

Safety procedures for electrical components, wiring, and cabling integrity.

Component Repair Safety Precautions

Safety guidelines for repairing sealed and intrinsically safe components.

Flammable Refrigerant Detection Safety

Procedures and restrictions for detecting flammable refrigerants, prohibiting open flames.

Refrigerant Handling Procedures and Compliance

Acceptable Leak Detection Methods

Methods for leak detection, refrigerant removal, evacuation, and safe recovery processes.

Equipment Labelling Requirements

Ensuring equipment is correctly labelled after de-commissioning and for containing flammable refrigerants.

Decommissioning and Charging Procedures

Detailed steps for decommissioning the unit and safe refrigerant charging procedures.

Installation Guide for Oasis Heat Pumps

System Installation Overview

General overview and initial steps for installing the heat pump system.

Heater Condition Check

Procedure for checking the heat pump unit's condition upon delivery and during installation.

Recommended Installation Locations

Guidance on selecting an appropriate outdoor location for optimal heat pump performance.

Airflow Clearance Requirements

Specifications for the minimum air clearances needed around the heat pump unit.

Ensuring Adequate Water Flow

Critical importance of sufficient water flow for heat pump efficiency and damage prevention.

Rubber Feet Installation

Recommendation for installing rubber feet to reduce vibration and aid drainage.

Condensate Drain Barb Installation

Instructions for fitting the condensate drain barb to manage water discharge.

Drainage and Condensation Management

Explanation of condensation formation and how to manage water discharge from the unit.

Plumbing Connections and Arrangements

Details on plumbing fittings, pipe types, and connection locations for the heat pump.

Electrical Connection Procedures

Essential steps and safety considerations for the electrical connection of the heat pump.

Operation of Oasis Heat Pumps

Main Controller Interface Overview

Description of icons, buttons, and their functions on the heat pump's main controller.

Controller Functions Explained

Detailed explanation of the various functions and operations controllable via the unit's interface.

Unit Start-Up and Shutdown

Instructions on how to turn the heat pump unit on and off using the controller.

Switching Operating Modes

Procedure for changing between Heating, Cooling, and Auto modes on the controller.

Setting the Target Temperature

How to adjust the desired water temperature using the controller's UP and DOWN buttons.

System Time Settings Configuration

Guide on setting the system time and date on the heat pump controller.

Configuring Timer Settings

Instructions for setting up the two-stage timing switch for the heat pump.

Cancelling Timer Settings

Steps to cancel or clear previously set timer functions for the heat pump.

Silent Operation Settings

How to activate and set the silent function for reduced noise operation.

Keyboard Lock Functionality

Instructions on how to lock and unlock the controller's keypad to prevent accidental changes.

Understanding Fault Codes

How to view and interpret fault codes displayed on the controller for troubleshooting.

Troubleshooting Heat Pump Faults

Electronic Control Fault Table

A comprehensive table listing electronic control faults, their reasons, and elimination methods.

Frequency Conversion Board Faults

Table detailing faults related to the frequency conversion board, their causes, and solutions.

Parameter List and Settings

List of adjustable parameters, their default values, and remarks.

Cable Specification Guidelines

Information on selecting appropriate cable sizes for the heat pump installation.

Refrigerant Saturation Temperature Comparison

Table comparing saturation temperatures for R410A and R32 refrigerants at different pressures.

Main Board Interface Diagram

Diagram illustrating the main board's connectors and interface points.

Main Board Interface Instructions

Detailed explanation of the input and output interfaces on the main control board.

Wire Control Interface Diagram

Diagram and definition of the wire control interface and its components.

Controller Interface Diagram

Diagram and definition of the controller interface and its connections.

Main Board Input;Output Interface Details

Detailed breakdown of the input and output signals and their corresponding connections on the main board.

Maintenance and Servicing Recommendations

Recommended Unit Servicing

Guidance on the recommended frequency and benefits of professional servicing for the heat pump.

Regular Unit Checks

Recommendations for regular checks to ensure the heat pump's performance and prevent issues.

Regular Checks Checklist

Specific items to check regularly for maintaining the heat pump's operational status.

Warranty Information and Registration

Warranty Service Requirements

Steps to follow when requesting warranty service for the heat pump unit.

Warranty Registration Process

Instructions and recommendation for registering the heat pump's warranty online or via email.

Oasis I Series Specifications

General IconGeneral
BrandOasis
ModelI Series
CategoryHeat Pump
LanguageEnglish

Related product manuals