Overview

The provided manual describes the Oasis Rapid Pro Heat Pump, a product designed for recreational pool and spa owners to extend their swim season with minimal running costs. It features stepless full DC inverter compressors, fans, and control systems, emphasizing energy efficiency and environmental friendliness.

Function Description

The Oasis Rapid Pro Heat Pump is a pool and spa heating system that utilizes heat pump technology to transfer heat from the air to the water. It offers three operating modes: Turbo, Smart, and Silence, each optimized for different conditions and energy efficiency levels. The unit is designed for easy installation and user-friendly operation via a digital touch screen control panel and a dedicated mobile application, "Inverter Life," compatible with both iOS and Android devices.

The heat pump's primary function is to heat pool and spa water, but it also has a cooling capacity. It incorporates an internal water flow switch to ensure adequate water circulation for optimal operation and protection against damage. The unit is equipped with an over-load protection system and a 3-minute restart delay to protect control circuit components and prevent short cycling. It also features automatic defrosting and a compulsory defrosting option.

The mobile app allows for remote control and monitoring of the heat pump, including setting temperatures, selecting operating modes, viewing real-time power consumption, and checking heating capacity percentage. It also provides a platform for sharing device control with family members.

Important Technical Specifications

The Oasis Rapid Pro Heat Pump comes in seven different models: RP14, RP16, RP18, RP22, RP32 (single phase), and RP32T, RP40T (three phase).

Performance Data (Water 26°C, Air 26°C):

  • Heating Capacity in Turbo Mode: Ranges from 9.0 kW (RP14) to 28.5 kW (RP40T).
  • Heating Capacity in Smart Mode: Ranges from 7.3 kW (RP14) to 24.0 kW (RP40T).
  • COP (Coefficient of Performance): Ranges from 7.9~5.2 (RP14) to 8.0~4.9 (RP40T).
  • Cooling Capacity: Ranges from 6.3 kW (RP14) to 19.5 kW (RP40T).
  • Sound Pressure at 1m: Ranges from 37.8~45.9 dB(A) (RP14) to 41.5~50.5 dB(A) (RP40T).
  • Sound Pressure at 10m: Ranges from 17.8~25.9 dB(A) (RP14) to 21.5~30.5 dB(A) (RP40T).
  • Rated Input Power (Air 15°C): Ranges from 0.19~1.7 kW (RP14) to 0.60~5.7 kW (RP40T).
  • Rated Input Current (Air 15°C): Ranges from 0.83~7.39 A (RP14) to 0.87~8.22 A (RP40T).
  • Advised Water Flux: Ranges from 3~4 m³/h (RP14) to 12~18 m³/h (RP40T).
  • Operating Air Temperature: -20~43°C.
  • Refrigerant: R32 GWP (global warming potential) - 675.
  • IPX Rating: IPX4.
  • Power Supply: 240V/1/50Hz (single phase) or 400V/3/50Hz (three phase).

Physical Dimensions (L x W x H):

  • RP14: 945 x 432 x 660 mm, 65 kg.
  • RP16/RP18: 1045 x 432 x 660 mm, 72 kg (RP16), 73 kg (RP18).
  • RP22: 1195 x 432 x 760 mm, 82 kg.
  • RP32/RP32T: 1264 x 536 x 956 mm, 122 kg (RP32), 132 kg (RP32T).
  • RP40T: 1364 x 536 x 956 mm, 147 kg.

Usage Features

  • Digital Touch Screen Controller: Provides intuitive control over the unit's functions, including power on/off, mode selection (Turbo, Smart, Silence), temperature adjustment, and timer settings.
  • Wi-Fi Connectivity: Allows for remote control and monitoring via the "Inverter Life" mobile app. The app enables users to adjust settings, view real-time data, and receive error notifications.
  • Multiple Operating Modes:
    • Turbo Mode: Offers 120%~20% heating capacity for fast heating, intelligently optimizing based on ambient and water temperatures for energy efficiency.
    • Smart Mode: Provides 100%~20% heating capacity, with intelligent optimization for energy saving.
    • Silence Mode: Offers 60%~20% heating capacity, ideal for night use with reduced noise levels.
  • Timer Function: A 24-hour system for scheduling on/off times, with options for daily or one-time settings.
  • Real-time Data Display: The controller and app show real-time power consumption and heating capacity percentage.
  • Adjustable Set Temperature: Users can set desired water temperatures within specified ranges (Auto: 12~40°C, Heating: 18~40°C, Cooling: 12~30°C).
  • Temperature Unit Conversion: Easily switch between Celsius (°C) and Fahrenheit (°F).
  • Error Code Display: The unit displays specific codes (e.g., E3 for no water protection, Ed for anti-freezing protection) to help diagnose issues.
  • Condensate Drainage: The unit discharges condensation water, similar to an air conditioner, and includes provisions for connecting drain barbs to direct water to a drainage point.

Maintenance Features

  • Regular Inspection: The manual emphasizes the importance of regular inspection of the condensate drain to prevent obstructions and ensure proper flow.
  • Water Flow Management: Critical to ensure sufficient water flow to the unit. The bypass valve allows for adjustment of water flow rate to achieve optimal performance and prevent damage. All piping must be thoroughly flushed before connecting the heater to prevent debris from damaging the flow switch.
  • Professional Installation and Repair: Installation, repair, or relocation must be completed by a fully qualified technician to avoid hazards and ensure warranty validity.
  • Genuine Spare Parts: Only genuine Oasis spare parts should be used to maintain product warranty.
  • Electrical Safety: Requires installation of a circuit protection device, good power connection, and earthing. An isolating switch must be installed nearby.
  • Clearances: Adherence to minimum clearances and recommended installation locations is crucial for efficient heating and proper ventilation.
  • Checks to the Refrigeration Equipment: Regular checks for leaks, adequate ventilation, and proper installation of components are required. The charge size and refrigerant type must be verified.
  • Checks to Electrical Devices: Periodic checks and inspection procedures are necessary to ensure safety and proper operation.
  • Cabling and Wiring: Cabling should be protected from external factors like wear, corrosion, and vibration.
  • Repairs to Intrinsically Safe Components: Only authorized personnel should repair or replace intrinsically safe components.
  • Detection of Flammable Refrigerants: Potential sources of ignition must be avoided in areas where the equipment is installed, and leak detection methods should be employed.
  • Removal and Evacuation: Procedures for refrigerant recovery, purging, and evacuation are outlined for qualified technicians.
  • Labelling: Proper labelling of refrigerant type and charge is required.
  • Recovery: Detailed procedures for recovering refrigerant from the system are provided, emphasizing safety and environmental considerations.
  • Decommissioning: Essential steps for decommissioning, including refrigerant recovery and electrical power isolation, are outlined.
  • Charging Procedures: Specific procedures for charging the system with refrigerant are provided, including leak testing and ensuring proper pressure.