44
1. Unscrew both screws (a) from the controller (b) and remove it from the base (c).
2. Remove cable inlet lids (d) and place the cables. Left cable inlet is for sensor cables,
right cable inlet is for power supply cables.
3. Place the base into the boiler and fasten it with the mounting hooks (e).
4. Carry out electrical connection, put the controller (a) back into the base, and fasten it
with screws (b).
d
e
b
4
d
b
a
d
e
a
c
b
a
The installation into a boiler panel cutout is carried out in the following way:
INSTALLATION INTO THE PANEL CUTOUT