future use.
Store all accessories with the unit in a dry, cool location.
REMOVING MINERAL BUILD-UP
Different water sources contain minerals and the sediment may cause mineral build-up in
the steamer and affect the free flow of steam.
NOTE: The best way to avoid mineral build-up is to use distilled or de-mineralised water.
If you are unable to do this it is recommended to use the mineral build-up removal
procedure.
Unplug the unit and allow to cool completely (at least 60 minutes). Remove all
accessories from the unit.
Remove the water tank cap and drain any remaining water from the water tank.
Slowly pour the mixture into the water tank.
Allow the unit to stand for 1-2 hours.
Drain the solution from the water tank.
If the mineral build-up still remains in the unit, repeat the above steps until all build-up is
removed.
Rinse the water tank with fresh water, drain and repeat until the vinegar odour is
eradicated.
Replace the water tank cap.
SPECIFICATION
Unit Weight (Bare): 0.568kg.
Water Tank Capacity: 240ml.
Steam Output Time: 130 seconds.
Steam Duration: 14-18 minutes.
Voltage: 110-120V, 50/60Hz.
Wattage: 700W
TROUBLESHOOTING
Problem
Possible Reasons
Solution
Unit fails to heat.
Unit is not plugged in.
Plug into mains power supply.
Switch is not activated.
Press the On/Off switch.
Unit heats up but
fails to steam.
Water tank is empty.
Refill the water tank according.
Mineral build-up in unit.
Follow the removing mineral
build-up guide.
Thermo-fuse breakdown.
Take to a certified service centre.