32
Trouble Cause Corrective measures
The machine does not operate though
the power switch is turned ON.
Power is not supplied.
A screw hasn't been removed from the
pick up spot for a certain amount
of time.
Too many screws were loaded into the
scooping hopper.
A foreign object (for example: a screw)
intruded into the main body.
The AC adapter is faulty.
Check the connection of the power
supply of the AC power adapter.
Take the screw out from the
pick up site.
Adjust the timer setting knob.
Reduce the quantity of screws in the
scooping hopper to a proper load
level.
Remove the foreign object.
Consult our service section.
 
[Model number UI315-15]
Screws do not ow.
Screws with a larger diameter than the
specied rail size were loaded or screws
with a different diameter were mixed
in together.
An insufcient quantity of screws are in
the scooping hopper.
Use screws with the specied
nominal diameter.
Remove the screws with the odd
nominal diameter.
Add a proper quantity of screws into
the scooping hopper.
10.
TROUBLESHOOTING
For safety, always unplug the AC adapter from the wall outlet before making any adjustments.