34
Trouble Cause Corrective Measure
A screw has fallen into the rail
groove.
Screws with a smaller diameter than the
specied rail size were loaded.
Screws with a shorter total length than
the rail groove width were loaded.
Use screws with the specied nominal
diameter and length.
No corrective measure is available.
Consult our service section.
The flow on the screw rail is not
working properly.
The clearance between the holding
plate and the head of the loaded screw
is low.
Screws with a spring washer having
one increment smaller than the
specied nominal rail size were loaded.
The rail is oily or dirty.
The rail does not vibrate.
(A screw is caught in the gap.)
The motor is worn malfunctioning.
Adjust the holding plate.
Adjust the vibration.
If, after following the instructions
written above, the machine still does
not function properly, consult our
service section.
Clean the rail.
Remove the screws caught in the
clearance.
If there is no screw that is caught,
consult our service section.
Check that the vibration level is
properly adjusted.
Replace the motor.
[Part No. : NSB 09182 #05]