Bulletin 947023 THE OILGEAR COMPANY 1
OILGEAR TYPE “PVG” PUMPS -
-048/-065/-075 (SERIES F1U)
SERVICE INSTRUCTIONS
Figure 1. Typical Oilgear “PVG” Open Loop Pump
PURPOSE OF INSTRUCTIONS
These instructions will simplify the installation,
operation, maintenance and troubleshooting of
Oilgear type “PVG” pumps.
Become familiar with the construction, principle of
operation and characteristics of your pump to help
you attain satisfactory performance, reduce shut-
down and increase the pump's service life. Some
pumps have been modified from those described in
this bulletin and other changes may be made
without notice.
REFERENCE MATERIAL
Fluid Recommendations .....................................................................................Bulletin 90000
Contamination Evaluation Guide.........................................................................Bulletin 90004
Filtration Recommendations ...............................................................................Bulletin 90007
Piping Information ...............................................................................................Bulletin 90011
Installation of Vertically Mounted Axial Piston Units ...........................................Bulletin 90014
PVG Open Loop Pumps, Sales........................................................................ Bulletin 47019-I
Pump Control Instructions, Series F1U
“P-1NN” Single Pressure Compensator............................................................Bulletin 947651
“P-1NN/F” Single Pressure Compensator w/Load Sense.................................Bulletin 947652
“P-1NN/H” Single Pressure Compensator w/H.P. Limiter
....................................Bulletin 947653
“P-1NN/G” Horsepower Limiter w/Load Sense .................................................Bulletin 947654
“P-2” Dual Pressure Compensator....................................................................Bulletin 947655
“P-C” Single Pressure - Soft Start.....................................................................Bulletin 947656
“P-A” or “P-B” Electronic Pressure Compensator .......................Bulletins 947556 and 947657
“P-CNN/H” Single Pressure - Soft Start w/H.P. Limiter ...............Bulletins 947558 and 947658
“P-2NN/H” Dual Pressure Compensator w/H.P. Limiter ..............Bulletins 947559 and 947659
“V-S25” Electro Hydraulic Servo Valve..............................................................Bulletin 947560
“V-M20” Electro Hydraulic Servo Valve .............................................................Bulletin 947561
OILG0457
Bulletin 947023
November 2009
THE OILGEAR COMPANY
2300 South 51st Street
Milwaukee, Wisconsin 53219
www.oilgear.com
Bulletin 947023

Questions and Answers

  • G
    glen09Aug 9, 2025
    Why is my OilGear Water Pump making excessive noise?
    • R
      robert40Aug 9, 2025
      Excessive noise in your OilGear Water Pump can stem from several causes. It may be due to the pump starting or stopping incorrectly under load, so verify the pump's operation procedure. Check for a low fluid level in the reservoir or insufficient supercharge, which can cause cavitation. Also, inspect the system for air leaks. Ensure the fluid isn't too cold or its viscosity too high, and inspect the suction line for obstructions, proper length, diameter, and bends. A broken or worn piston/shoe assembly or the pump rotating in the wrong direction can also cause excessive noise. Inspect these components and the pump's operational direction.
  • S
    Stacy ColeAug 14, 2025
    What to do if my OilGear F1U is excessively heating?
    • C
      Carol BrownAug 14, 2025
      If your OilGear Water Pump is excessively heating, several factors could be responsible. Start by verifying the pump's limitations to ensure it's not operating above its rated or peak pressure. Check the fluid level in the reservoir and the supercharge to rule out issues there. Inspect the hydraulic system for air leaks. Also, the heating could be caused by a worn piston pump. Finally, inspect for obstructions in the cooling provision or clogged coolers.
  • M
    Melinda CarterAug 19, 2025
    How to fix insufficient pump volume in my OilGear Water Pump?
    • D
      Derrick ArnoldAug 19, 2025
      Insufficient pump volume in your OilGear Water Pump can be caused by several factors. The delivery may be limited by a faulty control. Inspect the suction circuit for obstructions and verify supercharge volume. Ensure the drive motor speed is sufficient. Finally, inspect the cylinder barrel and valve plate mating surfaces for wear or grooves; replace if necessary.
  • T
    Tina LeonardAug 25, 2025
    What to do if my OilGear F1U Water Pump has an irregular operation?
    • T
      Timothy EverettAug 25, 2025
      If your OilGear Water Pump is operating irregularly, several issues could be the cause. A faulty control could be the problem, so inspect and replace components as needed. Low fluid level in the reservoir or insufficient supercharge can also lead to irregular operation, so verify these. Check the hydraulic system for air entering it, inspect for leaks, and inspect the pump components for wear. Also, faulty output circuit components can cause this issue, so inspect and replace them as needed.
  • A
    Alexander ReedAug 29, 2025
    How to troubleshoot unresponsive control in OilGear F1U Water Pump?
    • D
      David CunninghamAug 29, 2025
      An unresponsive or sluggish control in your OilGear Water Pump can be due to a couple of reasons. If you have “R” and “V” volume type controls, there might be low control input (pilot) pressure. Also, worn or damaged swashblock saddle bearings could be the issue; inspect and replace them if necessary.
  • C
    Christopher PopeSep 3, 2025
    What causes excessive pressure in OilGear Water Pump?
    • P
      Patrick WhitakerSep 3, 2025
      Excessive or high peak pressure in your OilGear Water Pump can be caused by faulty output circuit components. Check the relief valves.