4203-E
P-436
SECTION
3
DESCRIPTION
OF
PARAMETER
AND
SETTING
PROCEDURE
Initial
Setting
Value
No.
Parameter
Contents
Set
1
SetO
“CHIP
CON”
SW
is
active
7
Selects
CHIP
CON
switch
“active”
or
“specification
code”
according
to
the
setting.
_
Active
Spec.
code
0
“CHIP
WASH”
SW
is
active
Selects
CHIP
WASH
switch
“ac¬
tive”
or
“specification
code”
accord¬
ing
to
the
setting.
8
Active
Spec.
code
0
“WATER
GUN”
SW
is
active
Selects
WATER
GUN
switch
“ac¬
tive”
or
“specification
code”
accord¬
ing
to
the
setting.
9
Active
Spec.
code
0
10
“SPINDLE
THROUGH
AIR
BLOW"
SW
is
active
Selects
SPINDLE
THROUGH
AIR
BLOW
switch
“active”
or
“specifica¬
tion
code”
according
to
the
setting.
Active
Spec.
code
0
S-AIR
BLOW
is
active
without
spindle
is
zero
Sets
if
the
interlock
function,
that
disables
spindle
rotation
during
spindle-through
air
blow,
is
made
ineffective.
11
Ineffective
Effective
0
CHIP
WASH
is
turn
on
with
NC
RUN
Sets
whether
or
not
the
chip
wash¬
ing
function
is
activated
at
the
start
up
of
the
NC.
12
Activated
Not
0
activated
M09
doesn’t
turn
off
the
coolant
Sets
whether
or
not
M08
(coolant
ON)
is
turned
off
by
the
execution
of
M09
(coolant
group
OFF).
13
Not
turned
Turned
OFF
0
OFF
Sets
whether
or
not
M50
(oil-hole
low
pressure
coolant
ON)
is
turned
off
by
the
execution
of
M09
(cool¬
ant
group
OFF).
M09
doesn’t
turn
off
the
oil
hole
low
pressure
Not
turned
Turned
OFF
14
0
OFF
M09
doesn’t
turn
off
the
oil
hole
high
pressure
15
Sets
whether
or
not
M51
(oil-hole
high
pressure
coolant
ON)
is
turned
off
by
the
execution
of
M09
(coolant
group
OFF).
Not
turned
Turned
OFF
0
OFF
WI09
doesn’t
turn
off
the
air
blow
(Nozzle)
Sets
whether
or
not
M12
(nozzle
type
air
blow
ON)
is
turned
off
by
the
execution
of
M09
(coolant
group
OFF).
16
Not
turned
Turned
OFF
0
OFF
M09
doesn’t
turn
off
the
air
blow
(Adapter)
Sets
whether
or
not
M59
(adapter
type
air
blow
ON)
is
turned
off
by
the
execution
of
M09
(coolant
group
OFF).
17
Not
turned
Turned
OFF
0
OFF
M09
doesn’t
turn
off
the
oil
mist
Sets
whether
or
not
M07
(oil
mist
ON)
is
turned
off
by
the
execution
of
M09
(coolant
group
OFF).
18
Not
turned
Turned
OFF
0
OFF
M09
doesn’t
turn
off
the
work
shower
Sets
whether
or
not
M120
(work
shower
ON)
is
turned
off
by
the
ex¬
ecution
of
M09
(coolant
group
OFF).
19
Not
turned
Turned
OFF
0
OFF
M00/M01
doesn’t
turn
off
spindle/coolant
group
Sets
whether
or
not
spindle
stops
and
coolant
group
is
turned
off
by
the
execution
of
MOO
(program
stop)
or
M01
(optional
stop).
20
Not
turned
Turned
OFF
0