28
Alarm signals
General audio and visual alarm (display unit, indicator light)
Display in uncoded mode of the fault or alarm for the channel concerned
Outputs (optional)
RS232 link by infrared
on PC, maintenance and supervision software, EXCEL database
Ancillary software packages
Maintenance software COM 2100 and 2100S
Power supply
3 AAA alkaline batteries
or coated NiMH rechargeable battery pack
Battery autonomy
14 hours in standard operation
8 hours with pump
Charging time:
3 hours
Sealing: >= IP20 (IP66 following the catalogue)
Weight: 350 g
Dimensions: 110 high, 80 long, 45 deep (mm)
CE marking:
Marking in accordance with Electromagnetic Compatibility Directive 89/336/CEE: compliance with standard
EN 50270.
Explosive atmospheres ATEX 94/9/CE:
Marking in accordance with Explosive Atmospheres Directive ATEX 94/9/CE:
On MX 2100:
OLDHAM Arras
CE 0080
MX2100
II 1G II 2G I M1 I M2
EEx ia IIC T4 EEx ia I
EEx ia d IIC T4 EEx ia d I
INERIS 03ATEX0216
Do not open in explosive atmosphere
Serial number
Year of manufacture
On pump unit BP2100:
OLDHAM Arras
CE 0080
BP2100
II 1G I M1
EEx ia IIC T4 EEx ia I
INERIS 03ATEX0216
Do not open in explosive atmosphere
Serial number
Year of manufacture