CAUSE
No power.
The plug has not been inserted.
P1 Error Code
---------------------------------------------------------
In COOLING mode: environment tempera-
ture is lower than the set temperature
The temperature set is too close to ambient
temperature.
---------------------------------------------------------
Suction of outside air is obstructed.
The air lters are clogged by dust, uff or
animal hair.
---------------------------------------------------------
The drain pipe not connected or it is clogged.
---------------------------------------------------------
The appliance has a low level of refrigerant.
---------------------------------------------------------
Temperature setting is too high.
---------------------------------------------------------
The windows or doors of the room are open.
---------------------------------------------------------
The room area is too large.
---------------------------------------------------------
Heat sources are present inside the room.
The appliance bearing surface is not levelled.
---------------------------------------------------------
The air lters are clogged by dust, uff or
animal hair.
Thissoundiscausedbytherefrigerantow
inside the unit.
Theconditionerhasbeentiltedorlaidat.
Ambient temperature too low.
WHAT DO I DO?
Wait.
Insert the plug in the power socket.
The water collection tray is full.
Switch off the appliance, unload water
from the collection tray and then restart the
appliance.
---------------------------------------------------------
Reset temperature.
Lower the temperature set.
---------------------------------------------------------
Remove the obstructions.
Call the Service Centre.
Switchofftheapplianceandcleanthelters
following the instructions.
---------------------------------------------------------
Switch off the appliance, disconnect the
pipe, remove the possible obstruction and
reconnect the drain pipe
---------------------------------------------------------
Contact an assistance centre to have the appli-
ance inspected and the refrigerant topped-up
.
---------------------------------------------------------
Reduce the set temperature.
---------------------------------------------------------
Make sure all the windows and the doors
are closed.
---------------------------------------------------------
Check the cooling area again.
---------------------------------------------------------
Remove the heat sources if possible.
Placetheapplianceonaatandlevelledsurface
.
---------------------------------------------------------
Switchtheapplianceoffandcleanthelters
following the instructions.
It is totally normal.
Empty water before moving the appliance.
Air conditioner behaviour is normal.
MALFUNCTION
Theappliancedoesn’twork.
Theappliancedoesn’tswitchon.
The appliance only works for a small amount
of time.
Theappliancedoesn’tcoolefciently.
The appliance is noisy and vibrates ex-
cessively.
The appliance emits an abnormal sound.
Water leaks from the conditioner during
transport.
In cooling, night-time or automatic mode,
minimum speed cannot be selected.
8 - INCONVENIENCES AND POSSIBLE REMEDIES
Do not try to repair the appliance by yourself.
Iftheproblemhasnotbeensolved,pleasecontactyourlocalretailerortheclosestassistanceservice.
Supplydetailedinformationaboutthemalfunctionandtheequipmentversion.