EasyManua.ls Logo

Olimpia splendid DOLCECLIMA COMPACT User Manual

Olimpia splendid DOLCECLIMA COMPACT
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DOLCECLIMA
COMPACT
EN
LOCAL AIR CONDITIONER
INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE
Attenzione: rischio di incendio
Caution:
risk of re
Attention : risque d'incendie
Achtung: Brandrisiko
Atención: riesgo de incendio
Atenção: risco de incêndio
Let op: brandgevaar
Προσοχή: κίνδυνος πυρκαγιάς
Question and Answer IconNeed help?

Do you have a question about the Olimpia splendid DOLCECLIMA COMPACT and is the answer not in the manual?

Olimpia splendid DOLCECLIMA COMPACT Specifications

General IconGeneral
TimerYes
TechnologyAir - air
Timer typeDigital
Hose length1.5 m
Noise level63 dB
Hose diameter150 mm
Number of speeds2
Refrigerating mediumR410A
Cooling capacity (max)9000 BTU/h
Timer duration (maximum)12 h
Air conditioner functionsCooling, Dehumidifying, Ventilating
Refrigerating medium weight300 g
Suitable for room volume up to- m³
Cooling capacity in watts (max)- W
Cooling capacity in watts (nominal)2300 W
Cooling energy efficiency (EER, W/W)2.6
Product colorWhite
Connected load1100 W
AC input voltage220-240 V
AC input frequency50 Hz
Energy efficiency class (cooling)A
Energy efficiency class (heating)-
Hourly energy consumption (cooling)- kWh
Weight and Dimensions IconWeight and Dimensions
Depth355 mm
Width345 mm
Height703 mm
Weight23200 g
Package depth402 mm
Package width377 mm
Package height877 mm
Package weight28000 g

Summary

0 - Warnings

0.1 General Information

Introductory text thanking the user for choosing the appliance.

0.2 Symbols

Explains pictograms used for correct and safe operation of the machine.

0 - Warnings

0.3 General Warnings

Basic safety precautions for electrical equipment to reduce risks of fire, electric shocks, and injury.

0 - Warnings

0.4 Proper Use

Explains the intended use of the air conditioner for comfort and domestic purposes.

0.5 Hazardous Zones

Specifies environments where the climate controllers must not be installed due to safety risks.

0 - Warnings

0.6 Warnings for R290 Refrigerant Gas

Details critical safety warnings and precautions related to the R290 refrigerant gas used in the appliance.

1 - Description of the Appliance

1.1 List of the Components Supplied (Fig.5)

Lists all components included with the appliance, noting packaging and transport.

1.2 Identification of the Main Components (Fig.A)

Identifies the main parts of the appliance with corresponding numbers using Fig.A.

2 - Installation

2.1 How to Transport the Conditioner

Instructions for safe transport and handling of the appliance, emphasizing vertical position.

2.2 Warnings

Important warnings to prevent damage to the appliance during installation and operation.

2 - Installation

2.3 Mobile Installation

Steps for installing the air conditioner in a window or French window for mobile use.

2.4 Fixed Installation

Instructions for permanently installing the unit with fixed holes in windows or walls.

2.5 Electrical Connection

Guidelines for safely connecting the appliance to the power supply, including earthing.

2 - Installation

2.6 Drainage

How to connect the condensation discharge pipe, especially for dehumidifier use.

3 - Use of the Appliance

3.1 Control Panel Symbols and Keys (Fig.B)

Explains the symbols and buttons on the appliance's control panel for mode selection.

3.2 Remote Control Keys (Fig. C)

Details the functions of each button on the remote control for convenient operation.

3 - Use of the Appliance

3.3 Use of the Remote Control

Covers handling, battery insertion, replacement, and optimal placement of the remote for effective signal transmission.

3 - Use of the Appliance

3.4 Use of the Appliance

Covers preliminary operations before use and switching the appliance on/off.

3 - Use of the Appliance

3.5 Ventilation Mode (Fan)

Explains how to use the fan-only mode for air circulation without temperature or humidity control.

3.6 Cooling Mode (Cool)

Details the cooling function, temperature adjustment, and operation, including compressor activation.

3.7 Dehumidification Mode (Dry)

Explains the dehumidification mode and its specific operational requirements, including condensate drain connection.

3 - Use of the Appliance

3.8 Auto Mode (Automatic)

Describes the automatic mode that adjusts cooling and fan functions based on monitored room temperature.

3.9 Night Function

Details the night function for adjusting temperature automatically during sleep for enhanced comfort.

3.10 Timer Mode

Instructions for programming the appliance's switching on and off times with delay settings.

3 - Use of the Appliance

3.11 Setting the Unit of Measurement of Temperature

How to switch between Celsius and Fahrenheit display units on the machine.

3.12 Autorestart

Explains the autorestart function that restores previous settings after a power interruption.

4 - Maintenance and Cleaning

4.1 Cleaning

General instructions for cleaning the appliance and remote control with precautions.

4 - Maintenance and Cleaning

4.1.b Cleaning the Suction Filter

Detailed steps for cleaning the air filters to ensure efficient operation and alarm indication.

4.1.c Recommendations for Energy Saving

Tips to reduce energy consumption when using the appliance, such as keeping filters clean and doors closed.

4.2 Maintenance

Procedures for long-term storage and checks before resuming use, including fan-only drying.

4 - Maintenance and Cleaning

4.2.a Discharging Condensation

How to drain accumulated condensation from the lower tray when the appliance emits beeps.

4.2.b Error Codes

Explains error codes displayed on the panel and initial troubleshooting steps for common anomalies.

5 - Technical Data

6 - Inconveniences and Possible Remedies

7 - Wiring Diagram