ENGLISH
EN - 22
• Removethetransparentlabelremainingintheupperpartoftheadhesivesheet
andstickitoverthepreviousoneafxedtotheloadingpoint.
Avoidtheemissionoftheuorinatedgascontainedhere.
• Makesurethattheuorinatedgasisneverreleasedintotheatmosphereduring
installation, assistance and disposal.
• Wheneverauorinatedgasleakisdetected,theleakmustbefoundandrepaired
as quickly as possible.
ONLYqualiedpersonnelmustprovideassistanceonthisproduct.
Anyuseofuorinatedgasinthisappliance,e.g.duringmanualmovementofthe
product or re-loading the gas, must be compliant with the regulations regarding
determineduorinatedgreenhousegasesandanyapplicablelocallaws.
2.6.7 - Connection of the condensate drain line
Connect a drain pipe, of appropriate length, to the indoor unit condensate drain pipe, and block it with a strap.
Make it run inside the duct parallel to the system pipes, fastening it to the same using straps.
Donottightenthestrapsexcessivelyinordertopreventdamagetotheinsulation
of the pipes and narrow the drain pipe.
Wherepossible,makethecondensateliquidowdirectlyintoarainwatergutter.
If the drain pipe is fed into a sewage system, it is necessary to bend the pipe in
ordertocreateasiphon(gure25),inordertoavoidthediffusionofunpleasant
odours into the environment.
Thesiphonbendmustneverbeatalevelbelow1500mmfromthelowerwireof
theappliance(gure24).
Ifdrainingisintoarecipient(gure26),thismustneverbeclosedsoasnotto
prevent counter-pressures such to compromise the operation, and the pipe itself
must never reach the level of the liquid deposited.
Check the correct run-off of the condensate liquid through the relative pipe by very
slowlypouringapprox.1/2litreofwaterintothecollectiontrayoftheindoorunit
(gure27).