SECCO PIÙ - SECCO SUPER
Display:
Usually the display shows set point, press “Hr” button to see room humidity. Set point can be regulated
between 30 and 90, 5 by 5, pressing UP or DOWN. (only for Secco Super)To select minimum or
maximum fan speed, press the fan button.
Stand by mode:
To start and stop the unit pres Stand By button. In stand by mode every component is off, there is no
measuring and no programming is possible.
Dry mode:
Compressor and fan start if the difference between room humidity and set point is higher than 3 and if a
time higher than Cf” has passed after last stop. Compressor and fan keep going until the difference
between room humidity and set point is higher than -3. When compressor stops the fan keep going for
another 30 seconds. When the tank is full all components turn off, tank led turns on and the unit buzzes for
15 sec. Pressing one button during the 15 sec the buzz stops.
All inputs are saved in an eeprom, after a power failure the unit will restart considering last inputs.
Defrosting mode:
When there is ice on the evaporator (evaporator temperature < “Ft” and compressor on) the compressor
keep working for another 30 min, than it stops while the fan keep going until evaporator temperature >

Questions and Answers:

Olimpia splendid SECCO SUPER Specifications

General IconGeneral
BrandOlimpia splendid
ModelSECCO SUPER
CategoryHumidifier
LanguageEnglish

Summary

Seco Più - Seco Super Operation

Display Functionality

Shows set point and room humidity. Set point adjustable between 30-90, 5 by 5.

Stand By Mode Operation

Turns unit off, no measuring or programming possible. Press Stand By button to activate.

Dry Mode Operation

Compressor/fan start based on humidity difference and time. Auto-off when tank is full.

Defrosting Mode Logic

Activates when evaporator is iced, compressor stops after 30 min, fan continues.

Troubleshooting and Settings

Full Tank Alarm Deactivation

Deactivates full tank alarm by pressing UP+DOWN for 3 sec. Alarm resets when switch closes.

Probe and Temperature Alarms

Handles sensor damage (Hr/tE) and low evaporator temp (LO) alarms.

Self Test Procedure

Initiates unit diagnostics by pressing DOWN+Hr for 3 sec.

Setup Mode Configuration

Allows setting unit parameters by pressing Hr+UP for 3 sec in standby.

Default Parameter Values

Lists default values for compressor time, defrost temp, and stop time.