TECHNICAL FEATURES
Secco Prof
Power Supply 230V - 50Hz
Input Power (27C - 65% U.R.) 520 W – 2,2A
Max Input Power (32C - 80% U.R.) 620 W – 2,7A
Dehumidification Capacity 27C - 65% U.R. (liters) 18 /24 h
Dehumidification Capacity 32C - 80% U.R. (liters) 28 /24 h
Fan Speeds 1
Refrigerant type R 134A
Refrigerant quantity 0,230 kg
Air Flow
380 m
3
/h
Tank Capacity (liters) 10
Dimensions (HxWxD) mm 720 x 310 x 450
Weight 27 kg
Noise level (sound pressure) 53 dB(A)
Noise level (sound power) 62 dB(A)
Water Proof Level IPX1
OPERATING WORKING LIMITS
Max working conditions in dehumidification mode: DB / WB 35°C/31°C
Min working conditions in dehumidification mode: DB / WB C/1°C
Question and Answer IconNeed help?

Do you have a question about the Olimpia splendid Secco Prof and is the answer not in the manual?

Olimpia splendid Secco Prof Specifications

General IconGeneral
BrandOlimpia splendid
ModelSecco Prof
CategoryDehumidifier
LanguageEnglish

Summary

Technical Features

General Specifications

Key technical data including power, capacity, airflow, dimensions, and noise levels.

Operating Working Limits

Defines the environmental conditions for dehumidification mode operation.

Introduction and Control Panel

Control Panel Elements

Explanation of keys and display indicators on the dehumidifier's control panel.

Selecting Functions

Guide to activating standby mode, adjusting humidity set point, and choosing operating modes.

Function Details

Dehumidification Mode Operation

Details on compressor and fan operation based on humidity levels and set points.

Drying Mode Operation

Describes the continuous high-power operation for drying purposes.

Defrosting Mode

Explanation of the automatic defrost cycle for evaporator frost prevention.

Continuous Discharge Operation

Instructions for setting up and using the continuous drainage function.

Troubleshooting and Diagnostics

Alarm Codes

List of display indications, likely causes, and suggested solutions for common errors.

Autotest Mode

Procedure for initiating and controlling the unit's automatic test sequence.

Wiring Diagram