Troubleshooting
Equipment works
continuously for long
periods of time.
Condenser coil is dirty. N/A. Clean coil to remove
dust, lint and waste.
Evaporator coil blocked
by frost or frozen.
Door closure and seals
are rm and adequate
throughout perimeter.
Turn cooler o to defrost
coil. Do not to use a
cutter knife or blade for
handling. Inappropriate
use may scratch or cut o
components.
Doors remain open for a
long time or doors don’t
close.
Doors closed when not
used.
Do not allow doors
to remain open for
prolonged periods of
time.
Door magnetic seals do
not close or seal.
Seal wear. Adjust door or change
seals, if necessary.
Hot product load in
cabinet is excessive.
N/A. Allow enough time to cool
product.
Compressor does not
start, makes buzzing
noises or stops due to
thermal protector.
Voltage variation
is excessive or
undervoltage is observed.
If business lamps vary
their intensity.
Allow for voltage restore
and voltage increase.
Vent motor is protected
or burnt. Fan blade is
damaged.
Fan rotation without
variations and for
complete blade.
Call Customer Service
Center if required.
Condenser coil is dirty. N/A. Clean dust, lint and waste
from coil.
Insucient air ow or
blocked.
Remove objects that may
obstruct air ow or move
to provide enough space
around it.