ECD 15B / 40B / 90B / 150B - Installation and operating manual
5
Installation
Inlet pipe (1) size at least ½” (inner diameter > 13mm).
Collecting condensate line (3) size at least ¾ “.
At least 1% inlet pipe slope recommended.
Install ball valves (2) only.
Recommended connection (4) to water/oil separator.
1
2
The inclination of the unit must not exceed + / - 5° in both axes. If device is not installed
correctly it could cause faulty detecting of condensate level.
3
4
Connecting several condensate sources to one drain device causes operating problems (3).
Make sure that each drain source has its own drain device (4).