R02000 Service Manual
Printed in the U.S.A. © Copyright 2006 OMNIFILTER
5
Substance
Influent Challenge
Concentration mg/L
Maximum Permissible
Product Water
Concentration mg/L
Barium 10.0 ± 10% 2.0
Cadmium 0.03 ± 10% 0.005
Chromium (Hexavalent) 0.3 ± 10% 0.1
Chromium (Trivalent) 0.3 ± 10% 0.1
Copper 3.0 ± 10% 1.3
Lead 0.15 ± 10% 0.010
Radium 226/228 25 pCi/L ± 10% 5 pCi/L
Selenium 0.10 ± 10% 0.05
Total Dissolved Solids 750 ± 40 mg/L 187
Performance Test Data: Model # RO2000 Series B
Performance Indication: A sampling kit for analysis of TDS
The Omnifilter model RO2000 Series B reverse osmosis system contains a replaceable treatment
component critical for effective reduction of TDS (Total Dissolved Solids). The product water shall be
tested periodically to verify that the system is performing satisfactorily.
The TDS sampling kit is included with this system in a separate bag. This sampling kit will be used to
compare your kitchen tap water against the reverse osmosis drinking water to determine if the
membrane needs to be replaced.
This sampling kit includes: Two (2) sample bottles with labels, one (1) Padded envelope with mailing
label and one (1) Instruction sheet
Substance Influent Challenge Concentration Reduction Requirement
Cyst Minimum 50,000/mg/L 99.95%