Speed command value or
speed detection value
Output current
RUN command
“POS-SET”
Brake signal “BRK”
J95 Brake control Brake-release
Torque = 0% setting
Torque command
Servo lock
J70: Brake Control
Brake-release Timer
J72: Brake Control
Brake-applied Timer
J70: Brake Control
Brake-release Timer
J72: Brake Control
Brake-applied Timer
Servo lock
OFF
OFF
OFF OFFON
ON OFF
OFFON OFFON
ON ONOFF ONOFF
ASR integral term cancel
“P-SEL”
Vector control J96 bit 6 = 0 Operation time chart
J68 Brake Control
Brake-release Current
J96 bit6 0: Brake signal ON during position control stop
1: Brake signal released during position control stop
Output frequency
Output current
RUN command
“POS-SET”
Brake signal “BRK”
DC injection braking
DC injection
braking
OFF
OFF
OFF OFFON
ON OFF
ON OFF
J69 Brake Control
Brake-release Frequency
J68 Brake Control
Brake-release Current
J70: Brake Control
Brake-release Timer
J96 bit6 0: Brake signal ON during position control stop
1: Brake signal released during position control stop
V/f control J96 bit 6 = 0 Operation time chart
6 Vector Control and Applied Functions
6-60
M1 Series Standard Type User's Manual (I669)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron 3G3M1-A4030-ECT and is the answer not in the manual?

Omron 3G3M1-A4030-ECT Specifications

General IconGeneral
BrandOmron
Model3G3M1-A4030-ECT
CategoryInverter
LanguageEnglish

Related product manuals