2155411-6E
PIN No.
1
2
3
4
Signal
TRIG1
TRIG2
24VDC
0V
I/O
Input
Input
Input
Input
Fanction
Trigger input for CH1(*)
Trigger input for CH2(*)
Power Supply(24VDC)
Power Supply(0V)
1) Put on
1. Hook on the DIN rail
2. Push controller until the click sound
2) Take off
1. Pull hook to the outside
2. Lift controller from DIN rail
■ Fix by screw
It can be fixed by 2pcs of M4 screw. Fasten torque : within 0.49n/m
■Insert
Adapt the boss of lighting cable and channel mark
of controller. Insert cable to the controller until the
click sound.
■Release
Pull connector with pushing the boss
■Fix to DIN rail
Put on and take off from DIN rail with one-touch operation.
■Fix terminal block
1. Release terminal block by unfixing 2 screws.
2. Fix the wire to the terminal block by minus
screw fasten torque :0.22 – 0.25Nm
3. Insert male connector to female connector.
4.Fix the male connector by screw fasten
torgue:0.22-0.25Nm
■Parallel Connector
■I/O circuit
2.Installation
3.How to connect to light
6.Dimensions
4.Wiring
5.Part Names and Functions
Model
I/O type
Model Name
Power Supply Voltage
Currant Consumption
Lighting Channel
Applicable Lighting
Luminance
Control
Method
Luminance
Adjustment
External Interface
Dielectric Strength
Insulation Resistance
Ambient Temperature
Ambient Humidity
Vibration Resistance(destructive)
Shock Resistance (destructive)
Materials
Degree of Protection
Weight
Accessories
CONTINUOUS
mode
EXTERNAL
TRIGGER
mode
STOROBE
mode
Key
I/O
FL-STC10 FL-STC15 FL-STC20 FL-STC25
NPN PNP NPN PNP
DC24V±10%(Including ripple)
FL-□ series
Lighting ON continuously.
PWM fregency:100KHz,Control step:400 steps
Lighting ON syncronized with external trigger
"During the TRIG signal ON" or "0.1to99.9ms"
PWM fregency:100KHz,Control step:400 steps
Lighting ON syncronized with external trigger
(more than 2 times brighter than EXTERNAL TRIGGER mode)
Lighting time:0.01to5ms
Slide SW and Direction key setting
9bit binary input contol
Parallel I/O connector(mini D-SUB 15 PIN)
Terminal block(External Trigger 1CH/2CH, power supply)
AC1000V 50/60Hz 1min
20MΩ(100VDC)
Operating: 0to40℃, Storage: −15 to +60℃ (with no icing or condensation)
Operating and storage: 35%to85% (with no condensation)
10to150 Hz, (0.7mm double amplitude) 80 min each in X, Y, and Z directions
150 m/s
2
3 times each in 6 directions(up/down, left/right, forward/backward)
Polycarbonate
IEC60259 IP20
Main unit:100g, Packed state:170g
Instruction sheet,Terminal block connector
Lighting Controller 1CH type
MAX 36W,1.5A(Lighting Included)
1
Lighting Controller 2CH type
MAX 72W,3A(Lighting Included)
2
FL-STC
□□
Attention
Fix the controller by End Plate
Attention
Wire correctly, otherwise, it would be breakdown
Attention
- Use power supply DC24 (21.6 -26.4V) for 3 and 4 pin.
-
Supply voltage from safety voltage circuit. Use UL class 2 direct-current power source if UL approval needed.
Attention
Input signal more than MIN input time (ms). Otherwise the signal would not be recognized.
Attention
Do not pull cable without pushing boss.
Disconnection might happen.
Attention
Connect I/O ground to power supply ground.
Attention
Avoid to touch the terminals
* DI13 and DI14 of parallel connector has Lighting trigger. Make sure isolate another trigger terminal when
you use one trigger terminal.
(*1) 1 and 2pin of terminal block have Lighting trigger. Make sure isolate another trigger terminal when you
use one trigger terminal.
(*2) Prevent from chattering, otherwise the lighting timing would be missed.
(*3) see “8. lighting level setting by parallel input””
(*4) Memory function “ON”: The data stored in FLASH memory .
Memory function “OFF” : The data stored in RAM memory .
For more information please refer to “7. Setting ”
1
2
1
2
End plate
fixing hole
fixing hole
· Dimensions from DIN rall
DIN rail
PFP-100N(1m)
PFP-50N(0.5m)
PFP-100N2(1m)
(30.6)
(3.4)
89
2-M4
22
Parallel Connector
(mini D-SUB 15 pin
(female))
· NPN(FL-STC20/10)
· Electric Specifications
· PNP(FL-STC25/15)
PARALLEL
DI11 DI12 DI13 DO1DI14
DI6 DI7 DI8 DI10DI9
DI1 DI2 DI3 DI4 DI5
(2) Connector to lighting CH2
(only for FL-STC20/25)
(1) Connector to lighting CH1
(3) Parallel connector
Setting data input and error
output
(4) Terminal block
DC24V input and
Lighting trigger input
(5) Hook for fixing to
DIN rail
Operation(*)
(*)Operation and Display
Display(*)
(6) CH1 light emitting LED
ON at CH1 light emitting and blinking at CH1 setting process. Green LED.
(7) CH2 light emitting LED
ON at CH2 light emitting and blinking at CH2 setting process. Green LED.
(8) Digital display
Display lighting level, menu and setting value. Red LED.
(9) Mode change SW
Continuous mode <>Trigger mode <> Set mode exchange switch
(10) Cross key
Operation key to set value, select terms.
(11)CH/ENT key
- CONT,TRIG mode : Change CH for setting
- SET mode : Enter key to fix value
Please observe the following precautions for safe use of the products.
1.Installation Environment
· Do not use the product in environments where it can be exposed
to inflammable/explosive gas.
· To secure the safety of operation and maintenance, do not install
the product close to high-voltage devices and power devices.
2.Power Supply and Wiring
· The supply voltage must be within the rated range (DC21.6 to
26.4V including ripple 10%(peak to peak)).
· Reverse connection of power supply is not allowed. Connection to
AC power supplies also not allowed.
· Open-collector outputs should not be short-circuited.
· High-Voltage lines and power lines must be wired separately from
this product. Wiring them together or placing them in the same
duct may cause induction, resulting in malfunction or damage.
· Always turn off the power of the unit before connecting or
disconnecting cables.
3.Other Rules
· Do not use for safety circuit for human safe and nuclear power.
· Do not attempt to disassemble, deform by pressure, incinerate,
repair, or modify this product.
· When disposing of the product, treat as industrial waste.
· If you notice an abnormal condition such as a strange odor,
extreme heating of the unit, or smoke, immediately stop using the
product, turn off the power, and consult your dealer.
4. Regulations and Standards
This product is compliant with the standards below:
EN Standards(European Standards), EN61326-1
Electromagnetic environment : Industrial electromagnetic
environment
(EN/IEC 61326-1 Table 2)
Also, the following condition is applied to the immunity test of this product.
: There may be cases that Lighting brightness fluctuate Max 10%.
Please observe the following precautions to prevent failure to operate,
malfunctions, or undesirable effects on product performance.
1.Do not install the product in locations subjected to the following
conditions:
· Ambient temperature outside the rating
· Rapid temperature fluctuations
· Relative humidity outside the range of 35 to 85%
· Presence of corrosive or flammable gases
· Presence of dust, salt, or iron particles
· Direct vibration or shock
· Reflection of intense light (such as other laser beams, electric
arc-welding machines, or ultra-violet light)
· Direct sunlight or near heaters
· Water, oil, or chemical fumes or spray, or mist atmospheres
· Strong magnetic or electric field
2.Power Supply and Wiring
· Connect lightings and I/O lines first, then supply voltage source.
· If surge currents are present in the power lines, connect surge
absorbers that suit the operating environment.
· Before turning ON the power after the product is connected, make
sure that the power supply voltage is correct, there are no
incorrect connections (e.g. load short-circuit) and the load current
is appropriate. Incorrect wiring may result in break down of the
product.
· Use FL-XC cable to extend the cable length between lightings and
lighting controller. FL-XC can be used only one unit at the same
time. Do not connect FL-XC and FL-XC each other.
3.Maintenance and inspection
· Prevent from high pressure instruments and driving machines for
safty of operation and maintenance.
· Always turn off the power of the unit before connecting or
disconnecting cables.
· Do not use thinners, benzene, acetone, kerosene to clean the
Product.
●Meanings of Signal Words
●Alert statements
PRECAUTIONS ON SAFETY
PRECAUTIONS FOR SAFE USE
PRECAUTIONS FOR CORRECT USE
Indicates a potentially hazardous
situation which, if not avoided, may
result in minor or moderate injury or
in property damage.
CAUTION
CAUTION
Model
FL series Lighting for Image Processing
Lighting Controller
Do not use it exceeding the rated voltage.
There is a possibility of failure and fire.
Do not connect amplifier units to AC power
supply. Risk of explosion.
Indicates prohibition when there is a risk of
minor injury from electrical shock or other
source if the product is disassembled.
1.Specifications
PIN No.
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8
DI9
DI10
DI11
DI12
DI13
DI14
DO1
Signal
D1
D2
D3
D4
D5
D6
D7
D8
D9
CLR
SEL
SAVE
TRIG1
TRIG2
ERR
I/O
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Output
min-Input Time
0.5
(*3)
0.02
0.02
−
Fanction
Data 1bit(low)
Data 2bit
Data 3bit
Data 4bit
Data 5bit
Data 6bit
Data 7bit
Data 8bit
Data 9bit(High)
Error clear. (OFF⇒ON timing)
Select setting CH. OFF=1CH, ON=2CH
Save data D9 - D1 to memory at the timing of “save”
OFF⇒ON(*4)
CH1 Trigger Input (*1)(*2)
CH2 Trigger Input (*1)(*2)
ON at the Error happens
Item
Output
Input
NPN type(FL-STC20/10)
NPN Open-collector 30VDC 50mA max.
ON:residual voltage 1.2V max.
OFF:leakage current 0.1mA max.
ON:Short-circuited with 0V or 1.5V or less
OFF:Open(leakage current:0.1mA max.)
PNP type(FL-STC25/15)
PNP Open-collector 50mA max.
ON:residual voltage 1.2V max.
OFF:leakage current 0.1mA max.
ON:Supply voltage short-circuited or
supply voltage within 1.5v
OFF:Open(leakage current:0.1mA max.)
1) CONT/TRIG mode
Set Luminance value by D9 – D1, 9bit binary data.
Range 1 – 400 (binary 000000001 – 110010000)
2) STB mode
Set Strobe Lighting time by D9 – D1, 9bit binary data.
Range 0.01 – 5.00ms
(1 – 500 binary 000000001 – 111110100)
Each bit 1=ON, 0=OFF
①Lock off by pushing
boss
②Release cable
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8
DI9
DI10
DI11
DI12
DI13
DI14
D1
D2
D3
D4
D5
D6
D7
D8
D9
CLR
SEL
SAVE
TRIG1
TRIG2(*2)
DO1 ERR
1
2
3
TRIG1
TRIG2(*2)
24VDC
4 0V
DC24V
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8
DI9
DI10
DI11
DI12
DI13
DI14
D1
D2
D3
D4
D5
D6
D7
D8
D9
CLR
SEL
SAVE
TRIG1
TRIG2(*1)
DO1 ERR
1
2
3
TRIG1
TRIG2(*1)
24VDC
4 0V
DC24V
Parallel Connector
(*1) no use for FL-STC10 (*2) no use for FL-STC15
Parallel Connector
Terminal block
Internal circuit
Internal circuit
Terminal block
30
64.9
* FL-STC10/15 don’t have 2CH connector.
(UNIT:mm)
2-4.4×5.4Dia. (fixing hole)
Connector for Lightings(2CH) *
Connector for Lightings(1CH)
Terminal block
5.5(Fixing hole surface)
(22.5)
98
80
(89.9)
(*3)
0.5
Dimensions from fixing hole
Terminal block
(female)
Terminal block
(male)
PIN Location
(1) 1CH type
1CH mark
1CH mark 2CH mark
(2) 2CH type
Load
Load
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.
TRACEABILITY INFORMATION:
Importer in EU
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
Manufacturer
Omron Corporation,
Shiokoji Horikawa,Shimogyo-ku,
Kyoto, 600-8530 JAPAN
2 011
2
※Assembled product
FL-XCP2(Cable length:2m)