2155411-6E
PIN No.
1
2
3
4
Signal
TRIG1
TRIG2
24VDC
0V
I/O
Input
Input
Input
Input
Fanction
Trigger input for CH1(*)
Trigger input for CH2(*)
Power Supply(24VDC)
Power Supply(0V)
1) Put on
1. Hook on the DIN rail
2. Push controller until the click sound
2) Take off
1. Pull hook to the outside
2. Lift controller from DIN rail
Fix by screw
It can be fixed by 2pcs of M4 screw. Fasten torque : within 0.49n/m
■Insert
Adapt the boss of lighting cable and channel mark
of controller. Insert cable to the controller until the
click sound.
■Release
Pull connector with pushing the boss
■Fix to DIN rail
Put on and take off from DIN rail with one-touch operation.
■Fix terminal block
1. Release terminal block by unfixing 2 screws.
2. Fix the wire to the terminal block by minus
screw fasten torque :0.22 – 0.25Nm
3. Insert male connector to female connector.
4.Fix the male connector by screw fasten
torgue:0.22-0.25Nm
■Parallel Connector
■I/O circuit
2.Installation
3.How to connect to light
6.Dimensions
4.Wiring
5.Part Names and Functions
Model
I/O type
Model Name
Power Supply Voltage
Currant Consumption
Lighting Channel
Applicable Lighting
Luminance
Control
Method
Luminance
Adjustment
External Interface
Dielectric Strength
Insulation Resistance
Ambient Temperature
Ambient Humidity
Vibration Resistance(destructive)
Shock Resistance (destructive)
Materials
Degree of Protection
Weight
Accessories
CONTINUOUS
mode
EXTERNAL
TRIGGER
mode
STOROBE
mode
Key
I/O
FL-STC10 FL-STC15 FL-STC20 FL-STC25
NPN PNP NPN PNP
DC24V±10(Including ripple)
FL- series
Lighting ON continuously.
PWM fregency:100KHz,Control step:400 steps
Lighting ON syncronized with external trigger
"During the TRIG signal ON" or "0.1to99.9ms"
PWM fregency:100KHz,Control step:400 steps
Lighting ON syncronized with external trigger
(more than 2 times brighter than EXTERNAL TRIGGER mode)
Lighting time:0.01to5ms
Slide SW and Direction key setting
9bit binary input contol
Parallel I/O connector(mini D-SUB 15 PIN)
Terminal block(External Trigger 1CH/2CH, power supply)
AC1000V50/60Hz1min
20MΩ(100VDC)
Operating: 0to40, Storage: 15 to 60 (with no icing or condensation)
Operating and storage: 35%to85% (with no condensation)
10to150 Hz, (0.7mm double amplitude) 80 min each in X, Y, and Z directions
150 m/s
2
3 times each in 6 directions(up/down, left/right, forward/backward)
Polycarbonate
IEC60259 IP20
Main unit:100g, Packed state:170g
Instruction sheet,Terminal block connector
Lighting Controller 1CH type
MAX 36W,1.5A(Lighting Included)
1
Lighting Controller 2CH type
MAX 72W,3A(Lighting Included)
2
FL-STC
□□
Attention
Fix the controller by End Plate
Attention
Wire correctly, otherwise, it would be breakdown
Attention
- Use power supply DC24 (21.6 -26.4V) for 3 and 4 pin.
-
Supply voltage from safety voltage circuit. Use UL class 2 direct-current power source if UL approval needed.
Attention
Input signal more than MIN input time (ms). Otherwise the signal would not be recognized.
Attention
Do not pull cable without pushing boss.
Disconnection might happen.
Attention
Connect I/O ground to power supply ground.
Attention
Avoid to touch the terminals
* DI13 and DI14 of parallel connector has Lighting trigger. Make sure isolate another trigger terminal when
you use one trigger terminal.
(*1) 1 and 2pin of terminal block have Lighting trigger. Make sure isolate another trigger terminal when you
use one trigger terminal.
(*2) Prevent from chattering, otherwise the lighting timing would be missed.
(*3) see “8. lighting level setting by parallel input””
(*4) Memory function “ON”: The data stored in FLASH memory .
Memory function “OFF” : The data stored in RAM memory .
For more information please refer to “7. Setting ”
1
2
1
2
End plate
fixing hole
fixing hole
· Dimensions from DIN rall
DIN rail
PFP-100N1m
PFP-50N0.5m
PFP-100N21m
(30.6)
(3.4)
89
2-M4
22
Parallel Connector
(mini D-SUB 15 pin
(female))
· NPN(FL-STC20/10)
· Electric Specifications
· PNP(FL-STC25/15)
PARALLEL
DI11 DI12 DI13 DO1DI14
DI6 DI7 DI8 DI10DI9
DI1 DI2 DI3 DI4 DI5
(2) Connector to lighting CH2
(only for FL-STC20/25)
(1) Connector to lighting CH1
(3) Parallel connector
Setting data input and error
output
(4) Terminal block
DC24V input and
Lighting trigger input
(5) Hook for fixing to
DIN rail
Operation(*)
(*)Operation and Display
Display(*)
(6) CH1 light emitting LED
ON at CH1 light emitting and blinking at CH1 setting process. Green LED.
(7) CH2 light emitting LED
ON at CH2 light emitting and blinking at CH2 setting process. Green LED.
(8) Digital display
Display lighting level, menu and setting value. Red LED.
(9) Mode change SW
Continuous mode <>Trigger mode <> Set mode exchange switch
(10) Cross key
Operation key to set value, select terms.
(11)CH/ENT key
- CONT,TRIG mode : Change CH for setting
- SET mode : Enter key to fix value
Please observe the following precautions for safe use of the products.
1.Installation Environment
· Do not use the product in environments where it can be exposed
to inflammable/explosive gas.
· To secure the safety of operation and maintenance, do not install
the product close to high-voltage devices and power devices.
2.Power Supply and Wiring
· The supply voltage must be within the rated range (DC21.6 to
26.4V including ripple 10%(peak to peak)).
· Reverse connection of power supply is not allowed. Connection to
AC power supplies also not allowed.
· Open-collector outputs should not be short-circuited.
· High-Voltage lines and power lines must be wired separately from
this product. Wiring them together or placing them in the same
duct may cause induction, resulting in malfunction or damage.
· Always turn off the power of the unit before connecting or
disconnecting cables.
3.Other Rules
· Do not use for safety circuit for human safe and nuclear power.
· Do not attempt to disassemble, deform by pressure, incinerate,
repair, or modify this product.
· When disposing of the product, treat as industrial waste.
· If you notice an abnormal condition such as a strange odor,
extreme heating of the unit, or smoke, immediately stop using the
product, turn off the power, and consult your dealer.
4. Regulations and Standards
This product is compliant with the standards below:
EN Standards(European Standards), EN61326-1
Electromagnetic environment : Industrial electromagnetic
environment
(EN/IEC 61326-1 Table 2)
Also, the following condition is applied to the immunity test of this product.
: There may be cases that Lighting brightness fluctuate Max 10%.
Please observe the following precautions to prevent failure to operate,
malfunctions, or undesirable effects on product performance.
1.Do not install the product in locations subjected to the following
conditions:
· Ambient temperature outside the rating
· Rapid temperature fluctuations
· Relative humidity outside the range of 35 to 85%
· Presence of corrosive or flammable gases
· Presence of dust, salt, or iron particles
· Direct vibration or shock
· Reflection of intense light (such as other laser beams, electric
arc-welding machines, or ultra-violet light)
· Direct sunlight or near heaters
· Water, oil, or chemical fumes or spray, or mist atmospheres
· Strong magnetic or electric field
2.Power Supply and Wiring
· Connect lightings and I/O lines first, then supply voltage source.
· If surge currents are present in the power lines, connect surge
absorbers that suit the operating environment.
· Before turning ON the power after the product is connected, make
sure that the power supply voltage is correct, there are no
incorrect connections (e.g. load short-circuit) and the load current
is appropriate. Incorrect wiring may result in break down of the
product.
· Use FL-XC cable to extend the cable length between lightings and
lighting controller. FL-XC can be used only one unit at the same
time. Do not connect FL-XC and FL-XC each other.
3.Maintenance and inspection
· Prevent from high pressure instruments and driving machines for
safty of operation and maintenance.
· Always turn off the power of the unit before connecting or
disconnecting cables.
· Do not use thinners, benzene, acetone, kerosene to clean the
Product.
●Meanings of Signal Words
●Alert statements
PRECAUTIONS ON SAFETY
PRECAUTIONS FOR SAFE USE
PRECAUTIONS FOR CORRECT USE
Indicates a potentially hazardous
situation which, if not avoided, may
result in minor or moderate injury or
in property damage.
CAUTION
CAUTION
Model
FL series Lighting for Image Processing
Lighting Controller
Do not use it exceeding the rated voltage.
There is a possibility of failure and fire.
Do not connect amplifier units to AC power
supply. Risk of explosion.
Indicates prohibition when there is a risk of
minor injury from electrical shock or other
source if the product is disassembled.
1.Specifications
PIN No.
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8
DI9
DI10
DI11
DI12
DI13
DI14
DO1
Signal
D1
D2
D3
D4
D5
D6
D7
D8
D9
CLR
SEL
SAVE
TRIG1
TRIG2
ERR
I/O
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Output
min-Input Time
0.5
(*3)
0.02
0.02
Fanction
Data 1bit(low)
Data 2bit
Data 3bit
Data 4bit
Data 5bit
Data 6bit
Data 7bit
Data 8bit
Data 9bit(High)
Error clear. (OFFON timing)
Select setting CH. OFF=1CH, ON=2CH
Save data D9 - D1 to memory at the timing of “save”
OFFON(*4)
CH1 Trigger Input (*1)(*2)
CH2 Trigger Input (*1)(*2)
ON at the Error happens
Item
Output
Input
NPN type(FL-STC20/10)
NPN Open-collector 30VDC 50mA max.
ON:residual voltage 1.2V max.
OFF:leakage current 0.1mA max.
ON:Short-circuited with 0V or 1.5V or less
OFF:Open(leakage current:0.1mA max.)
PNP type(FL-STC25/15)
PNP Open-collector 50mA max.
ON:residual voltage 1.2V max.
OFF:leakage current 0.1mA max.
ON:Supply voltage short-circuited or
supply voltage within 1.5v
OFF:Open(leakage current:0.1mA max.)
1) CONT/TRIG mode
Set Luminance value by D9 – D1, 9bit binary data.
Range 1 – 400 (binary 000000001 – 110010000)
2) STB mode
Set Strobe Lighting time by D9 – D1, 9bit binary data.
Range 0.01 – 5.00ms
(1 – 500 binary 000000001 – 111110100)
Each bit 1=ON, 0=OFF
Lock off by pushing
boss
Release cable
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8
DI9
DI10
DI11
DI12
DI13
DI14
D1
D2
D3
D4
D5
D6
D7
D8
D9
CLR
SEL
SAVE
TRIG1
TRIG2(*2)
DO1 ERR
1
2
3
TRIG1
TRIG2(*2)
24VDC
4 0V
DC24V
DI1
DI2
DI3
DI4
DI5
DI6
DI7
DI8
DI9
DI10
DI11
DI12
DI13
DI14
D1
D2
D3
D4
D5
D6
D7
D8
D9
CLR
SEL
SAVE
TRIG1
TRIG2(*1)
DO1 ERR
1
2
3
TRIG1
TRIG2(*1)
24VDC
4 0V
DC24V
Parallel Connector
(*1) no use for FL-STC10 (*2) no use for FL-STC15
Parallel Connector
Terminal block
Internal circuit
Internal circuit
Terminal block
30
64.9
* FL-STC10/15 don’t have 2CH connector.
(UNIT:mm)
2-4.4×5.4Dia. (fixing hole)
Connector for Lightings(2CH) *
Connector for Lightings(1CH)
Terminal block
5.5Fixing hole surface
(22.5)
98
80
(89.9)
(*3)
0.5
Dimensions from fixing hole
Terminal block
(female)
Terminal block
(male)
PIN Location
(1) 1CH type
1CH mark
1CH mark 2CH mark
(2) 2CH type
Load
Load
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.
TRACEABILITY INFORMATION:
Importer in EU
Omron Europe B.V.
 Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
Manufacturer
Omron Corporation,
Shiokoji Horikawa,Shimogyo-ku,
Kyoto, 600-8530 JAPAN
2 011
2
Assembled product
FL-XCP2(Cable length:2m)
Question and Answer IconNeed help?

Do you have a question about the Omron FL Series and is the answer not in the manual?

Summary

Safety Precautions and Warnings

Meanings of Signal Words

Defines signal words like CAUTION to indicate potential hazards and their severity.

General Safety Warnings

Highlights critical safety warnings for installation, operation, and handling to prevent injury or damage.

Specifications

Installation Guide

DIN Rail Mounting

Instructions for attaching the controller to a DIN rail using a one-touch operation.

Screw Mounting

Method for securing the controller using screws, with torque specifications.

Light Connection

Connecting Lighting Cables

Procedure for inserting and securing lighting cables into the controller's connectors.

Disconnecting Lighting Cables

Procedure for safely releasing and removing lighting cables from the controller.

Wiring Instructions

Terminal Block Wiring

Details on fixing wires to the terminal block and connecting male/female connectors.

Parallel Connector Wiring

Guidance for connecting the parallel connector, including pin assignments and functions.

Part Identification

Physical Dimensions

Usage Precautions

Installation Environment

Guidelines for suitable installation environments, avoiding gas, dust, and electrical interference.

Power Supply and Wiring

Precautions for correct power supply voltage, wiring, and preventing short circuits.

General Usage Rules

Rules for safe operation, maintenance, disposal, and handling abnormal conditions.

Parameter Setting

Mode Selection and Configuration

Setting the controller to CONTINUOUS, EXTERNAL TRIGGER, or STROBE mode.

Lighting Level Adjustment

Setting the light intensity using the controller's keys or parallel input.

Memory Function

Parallel Input Settings

Parallel Input Process

Details on setting light intensity or strobe time via parallel input signals.

Key Lock Function

Locking and Unlocking Controls

Instructions for enabling and disabling the key lock to prevent accidental changes.

Error Message Reference

Overview

The OMRON Model FL-STC is a lighting controller designed for image processing lighting controllers. It offers precise control over various lighting conditions, making it suitable for a wide range of industrial automation and inspection applications.

Function Description

The FL-STC controller provides three primary lighting modes: Continuous (CONT), External Trigger (TRIG), and Strobe (STB).

  • Continuous Mode (CONT): In this mode, the lighting is continuously ON. Users can adjust the lighting level from 1 (MIN) to 399 (ALL MAX) using a cross key interface. The digital value displayed on the controller is synchronized with the actual light intensity, allowing for real-time adjustments. The system automatically saves the set value after 5 seconds of inactivity.

  • External Trigger Mode (TRIG): This mode enables lighting to be controlled by an external trigger input. Similar to continuous mode, the lighting level can be adjusted from 1 (MIN) to 399 (ALL MAX). The digital value is synchronized with light intensity, and settings are automatically saved. The timing chart for TRIG mode illustrates that the light emits during the "Pulse ON time" (Tpulse-on) after a "Pulse delay time" (Tdelay) following the trigger input (TRIG1/TRIG2 ON). The pulse is ignored if the light is already emitting. Emission delay can be set from 0-999ms, and emission time from 0.1-99.9ms (or "ALL" for continuous emission during trigger ON).

  • Strobe Mode (STB): This mode provides lighting that is approximately two times brighter than the other modes, also controlled by an external trigger. The strobe settings include "Pulse ON time" (Pon) from 0.1ms to 99.9ms, "Pulse Delay time" from 0ms to 999ms, and a "Strobe setting" from 0.01ms to 5.00ms. The timing chart for STB mode shows a "Strobe ON time" and an "Invalid period of re-trigger input," which is 12 times the strobe time. For 2-channel controllers, if one channel is set to STB mode, the other channel automatically switches to STB mode.

The device also features a Memory Function (MEM), which is particularly useful for external control. When set to "ON," data is stored in FLASH (nonvolatile) memory, retaining settings even after power loss. Data saving requires approximately 2 seconds, and a minimum interval of 2 seconds is needed between a "SAVE" signal and the next "TRIG" signal. When set to "OFF," data is stored in RAM (volatile) memory, reverting to the last saved data upon power off.

A Key Lock Function is available to prevent accidental changes to settings. By pushing the CH/ENT key for 5 seconds in CONT or TRIG mode, all settings are locked. In this state, only the light intensity value display for each channel can be changed. To release the key lock, the CH/ENT key must be pushed again for 5 seconds.

Important Technical Specifications

The FL-STC series offers various models, including FL-STC10, FL-STC10S, FL-STC20, and FL-STC20S, differing primarily in the number of lighting channels (1 or 2 channels) and lighting controller type (standard or strobe).

  • Power Supply: 24 VDC ±10%
  • Current Consumption:
    • FL-STC10/FL-STC10S: Max 300 mA (lighting excluded)
    • FL-STC20/FL-STC20S: Max 400 mA (lighting excluded)
  • Lighting Control:
    • Continuous: Lighting ON continuously.
    • Trigger: Lighting ON only when TRIG1/TRIG2 are ON.
    • Strobe: Lighting ON only when TRIG1/TRIG2 are ON (approx. 2 times brighter).
  • Method: PWM (Pulse Width Modulation) control (0-399 steps).
  • Storage: Stores data in FLASH memory (nonvolatile) (approx. 2 seconds required for data saving).
  • Luminance Key: Sets luminance value by D9-D1, 9-bit binary data (range 1-400).
  • Strobe Key: Sets strobe lighting time by D9-D1, 9-bit binary data (range 0.01-5.00ms).
  • External Trigger/External Trigger (TRIG1/TRIG2) Input:
    • Input voltage: 5 VDC/12 VDC/24 VDC.
    • Input current: 5 mA/12 mA/24 mA.
  • Ambient Temperature: Operating 0 to 40°C, Storage -15 to 60°C (with no icing or condensation).
  • Ambient Humidity: Operating 35 to 85% RH, Storage 35 to 85% RH (with no icing or condensation).
  • Degree of Protection: Main unit: IP40 (IEC60529), Terminal block: IP00 (IEC60529).
  • Weight: Main unit: approx. 177g, Terminal block: approx. 18g.

Usage Features

  • Installation: The device can be installed on a DIN rail. The terminal block is detachable for easier wiring. It is crucial to connect the power supply correctly, ensuring the positive terminal is connected to +24V and the negative to 0V. Incorrect wiring can damage the unit.
  • Wiring: The manual provides detailed wiring diagrams for power supply, external trigger, and parallel input/output. It emphasizes using a parallel connector (XW4B-02B1-H1) for parallel input and output, and a parallel connector (XW4B-04B1-H1) for parallel input.
  • Parallel Input for Lighting Level Setting: The controller supports lighting level setting via parallel input. This allows for changing the light intensity value in CONT/TRIG modes and strobe emission time in STB mode using D1-D9 binary data. The SEL input selects the channel (OFF: CH1, ON: CH2), and the SAVE input fixes the value.
  • Error Messages: The device provides error messages (Er1-Er7) to indicate issues such as overcurrent (Er1-Er3), write errors by parallel input (Er4), no light connected (Er5-Er6), or overvoltage from the power supply (Er7). Each error message comes with a recommended recovery action, typically involving shutting down the controller, checking wiring and light conditions, and then restarting.

Maintenance Features

  • Cleaning: To ensure the safety of operation and maintenance, the device must be installed and maintained by qualified personnel. For cleaning, use a soft, dry cloth. Do not use thinner, benzene, acetone, or kerosene, as these can damage the product.
  • Troubleshooting: The error message system (Er1-Er7) assists in diagnosing and resolving common issues. If an error persists despite following the recommended recovery actions, it may indicate a defect in the product (light or controller), requiring further inspection or replacement.
  • Safety Precautions: The manual outlines crucial safety precautions, including warnings against electric shock, fire, and product damage. It advises against disassembling, modifying, or repairing the product, and warns against touching the terminal block while power is supplied. It also emphasizes the importance of proper wiring and avoiding looking directly at the light during mode changes, as it may flash.

Omron FL Series Specifications

General IconGeneral
BrandOmron
ModelFL Series
CategoryLighting Equipment
LanguageEnglish

Related product manuals