240
Precautions
Operation
If two or more ON or OFF times have been specified at the same
time, the first input ON time or the last input OFF time take prece-
dence over the other ON or OFF times.
Note: Withtheabovesetting,theoutput is continuouslyproduced
without interruption, because theONtime of program1and
OFF time of program 2 are valid.
The ON and OFF times can be set to the same value, but the timer
will not operate.
(Example: if both the ON and OFF times are set to 10:30 a.m.,
Monday, the timer does not produce any output.)
After data has been set, note that pressing the TMR/
P
key to
change the operation between the timer and pulse operation will
cause the set data to be lost.
If a power failure occurs, the output is turned off and the indicators
go off during the power failure.
WARNING
The H5F has a built-in lithium battery. When disposing of an
entire timer containing a lithium battery, be sure to do so prop-
erly. Lithium batteries may explode if incinerated, causing fire
or severe burns.
Also, do not touch the input terminals of any H5F timer while
power is being to the timer.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. L15-E1-3
!

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron H3BA and is the answer not in the manual?

Omron H3BA Specifications

General IconGeneral
Time Range0.05 s to 300 h
Output TypeRelay
Contact FormDPDT
WeightApprox. 200 g
Operating Temperature-10 to 55°C
Storage Temperature-25 to 65°C
Dimensions48mm x 48mm x 78mm
TypeSolid-state timer