Do you have a question about the Omron H3CR Series and is the answer not in the manual?
Time Range | 0.05 seconds to 300 hours |
---|---|
Output Type | Relay |
Number of Pins | 8 or 11 (depending on model) |
Type | Solid State Timer |
Mounting Type | DIN Rail |
Operating Temperature | -10 to 55°C |
Contact Rating | 5A at 250V AC |
Contact Configuration | SPDT |
Storage Temperature | -25 to 65°C |
Operating Modes | On-delay, One-shot, Interval, Flicker, Signal On/Off |
Details for 11-pin and 8-pin H3CR-A models, covering output, supply, input, time range, and modes.
Explains the numbering system for H3CR-A models, including pins, input, output, and suffixes.
Lists optional accessories like mounting adapters, tracks, sockets, covers, and clips.
Covers operating modes, pin types, input/output, mounting, and standards for H3CR-A.
Details time ranges for standard and double H3CR-A models.
Specifies voltage, consumption, input types, and control output ratings.
Covers accuracy, timing, electrical strength, noise immunity, and durability.
Details ambient conditions, EMC, protection degree, and weight.
Graph showing expected switching operations based on load current.
Repeats supply voltage, consumption, and output specs with additional notes.
Covers accuracy, timing, electrical strength, noise immunity, and durability.
Details ambient conditions, EMC, case color, and weight.
Illustrates the internal functional blocks for H3CR-A/AS and H3CR-AP models.
Explains the functions of Start, Reset, Gate inputs and Control output.
Shows timing diagrams for ON-delay and Flicker modes.
Shows timing diagrams for Delay, Interval, and One-shot modes.
Illustrates the timing for gate signal input in ON-delay mode.
Shows timing diagrams for Signal OFF-delay, Interval, Signal ON/OFF-delay, and One-shot modes.
Timing diagrams for ON-delay, Flicker ON start, Interval, and One-shot modes for A8/A8S models.
Timing diagrams for ON-delay, Flicker ON start, Interval, and One-shot modes for A8E models.
Shows dimensions for H3CR-A series models and connecting sockets.
Displays dimensions of the timer with set rings and connecting sockets.
Illustrates terminal connections for H3CR-A, AS, and AP models.
Illustrates terminal connections for H3CR-A8, A8S, and A8E models.
Explains wiring for no-contact and contact inputs, including signal level details.
Explains voltage input wiring for H3CR-AP, including no-contact, contact, and signal levels.
Shows examples for ON-delay and Flicker modes.
Examples for Gate Signal control and Flicker Reset.
Examples for Flicker, ON/OFF-delay, and OFF-delay operations.
Examples for Signal OFF-delay and Interval operations.
Ordering details for H3CR-F Flicker OFF and ON start models.
Explains the numbering system for H3CR-F models.
Lists optional accessories like mounting adapters, tracks, sockets, and clips.
Covers general specs and detailed time ranges for H3CR-F.
Specifies voltage, consumption, output ratings, accuracy, and timing.
Details ambient conditions, EMC, enclosure ratings, and weight.
Shows switching performance graph and identifies front panel controls.
Illustrates internal blocks and explains input/output functions for H3CR-F.
Timing diagrams for Flicker OFF start and Flicker ON start modes.
Ordering details for time-limit contact and dual output models.
Explains the numbering system for H3CR-G models.
Lists optional accessories like mounting adapters, tracks, sockets, and clips.
Covers general specs and detailed time ranges for H3CR-G.
Specifies voltage, consumption, output ratings, accuracy, and timing.
Details ambient conditions, EMC, enclosure ratings, and weight.
Shows switching performance graph and identifies front panel controls.
Locates time range and transfer time selectors and their displays.
Illustrates the internal functional blocks for H3CR-G8L and H3CR-G8EL.
Explains input and output functions for the H3CR-G timer.
Shows timing diagrams for star operation, transfer time, and indicators.
Ordering details for S-series (12s) and M-series (12min) H3CR-H timers.
Explains the numbering system for H3CR-H models.
Lists optional accessories like mounting adapters, tracks, sockets, and clips.
Covers general specs and detailed time ranges for H3CR-H.
Specifies voltage, consumption, output ratings, accuracy, and timing.
Details ambient conditions, EMC, enclosure ratings, and weight.
Shows switching performance graph and identifies front panel controls.
Illustrates functional blocks and explains Reset input and Control output functions for H3CR-H.
Shows timing diagrams for H3CR-H8L, H3CR-H8RL, and H3CR-HRL models.
Explains how to use selectors for time unit, range, and operating mode selection.
Details mode selection and time setting for H3CR-A multifunctional timers.
Explains time setting procedures for H3CR-F, G, and H timers.
Details using Time Setting Rings for setting specific times and limiting ranges.
Details dimensions and mounting for Y92F-30, Y92F-70/73, and Y92F-71/74 adapters.
Shows dimensions, terminal arrangement, and mounting holes for P2CF-08 sockets.
Shows dimensions, terminal arrangement, and mounting holes for P2CF-11 sockets.
Shows dimensions and terminal arrangement for P3G-08 and P3GA-11 sockets.
Details the Y92A-48G terminal cover, its dimensions, and application.
Shows dimensions for PFP mounting tracks, end plate, and spacer.
Details the Y92A-48B protective cover and its features.
Shows hold-down clips for specific socket types.
Explains using Time Setting Rings for setting specific times and limiting ranges.
Advises on setting, power supply, operating environment, and noisy locations.
Outlines conformance conditions, control board mounting, and other safety advice.
Specific advice on power supply and input/output wiring for H3CR-A/-AS/-AP models.
Details correct input wiring to prevent short-circuits for H3CR-A/-AS.
Details H3CR-AP wiring and common notes on input circuit independence and output isolation.
Advises on power supply, wiring, and operation intervals for H3CR-H.
Explains input/output wiring and other advice for H3CR-H models.