EN/IEC Standards
The insulation system between the power supply circuit and input-
output terminals provides basic insulation.
Therefore connect the output terminals only to circuits without
exposed conductive parts. If a connection to a Safety Extra Low
Voltage (SELV) circuit is desired, supplementary insulation must be
provided.
Use crimp type cable lug terminals with insulating sleeves for
wiring.
Be sure to mount a surface-mounting model (H5S-@FA@/-@FB@)
in an enclosure.
The relationship between load current and ambient air temperature
is shown by the range below for 2-circuit models.
If wires with a temperature rating of 105 °C or higher are used,
refer to the derating curve in Specifications on page 3.
Control system: Electronic
Types of automatic operation: Weekly models - Type 1 BSTU
Yearly models - Type 2 BSTU
Protective class: Class 0
Rated impulse withstand voltage: 2,500 V AC
Ball-pressure test temperature (enclosure material): 125°C
Basic Use
Prior to Using
Before setting the parameters necessary for each operation, the operation of each circuit (output) must be determined. Begin by setting initial
setting mode as required.
40
30
20
10
0
10 0 20 40 5560 80
Ambient temperature (°C)
Total current (A)
Open the front cover.
Determine and
set the operation
of each circuit (output).
Set initial setting mode.
The Initial Setting mode must be
set to use the following functions.
Common to all models:
Next Operation Display Switching
Weekly models:
Time Counter/Total Counter Display
Time Adjustment Input
Manual Operation on Recovery
from Power Failure
Bank Switching
Yearly models:
Time Counter/Total Counter
Display
(See note.)
Time Adjustment Input (See note.)
Manual Operation on Recovery
from Power Failure (See note.)
Season Switching
Date Format Selection
Summer Time (DST) Adjustment
Note: 2-circuit models only
Set as necessary:
Note: Pull the front cover
open with your
fingertips.
Note: Use the tip of a ball-
point pen, or other
sharp instrument, to
make the settings.
For details, refer to Using Advanced Functions on
page 23.
HOLIDA
ON
AUTO
OFF
OUT
SATFRITHUWEDTUEMONSUN
P2
P1
RUN
OUT1
OUT2
DMY
WR
m/PLS
h
Timer operation Pulse operation
OUT
R
PULSE
TIMER
HOLID
A
SATFRITHUWEDTUEMONSUN
OUT1
OUT2
TEST
YEAR CYCLE CLEARTIME ADJ
DMY
WR
I
h
ON
AUTO
OFF
m/PLS
Note:
These settings
are not required
to use the basic
Time Switch
functions.
To enable operation
according to the
settings that you
made, first make the
settings and then set
the Output ON/OFF
Switch to AUTO and
the Mode Switch to
RUN.