1
New Product
Digital Timer
H5CZ
Easy to Use and Easy to Read.
Basic Features
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability
Power supply circuit and input circuits are isolated for safety and
reliability.
Set value limit function prevents unexpected operation of output
devices caused by setting mistakes.
Output counter function helps in managing the service life of the
Timer or the load.
Other Features
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection.
Features
Basic Features
Better Readability
Character Height of 10 mm with a Wide Viewing Angle.
The Easiest Operation
Operation is simplified by the Up/Down
Keys for each digit on 4-digit.
Safety and Reliability
Isolated Power Supply and Input Circuits
*1
Power supply circuit and input circuits are isolated for safety and
reliability.
Previous non-isolated timers had wiring restrictions and could be damaged if
wired incorrectly. The H5CZ removes these worries.
*1. H5CZ with 100 to 240-VAC specifications.
Set Value Limit
You can set an upper limit for the set value to prevent unexpected
operation of output devices caused by setting mistakes.
Output Counter
The output counter counts the number of times the output turns ON
(alarm display, count monitoring, count in increments of 1,000). This
counter is useful in managing the service life of the Timer or the load.
Other Features
Models with Instantaneous Contact Output
Models with instantaneous contact outputs have been added for use
with self-holding circuits and as auxiliary relays. These models are
also convenient when replacing analog timers.
Waterproof, Dust-proof Structure (UL508 Type
4X and IP66)
Worry-free application is possible in locations subject to water.
Note: When the Y92S-29 Waterproof Packing is used.
Key Protection
Select from any of seven protection patterns. Use the best one for the
application.
New Modes
Modes, such as a stopwatch mode (Mode S), have been added.
Select any of 15 modes.
Refer to Safety Precautions on page 29.
10 mm
(actual size)
Clear
Confirmation
Easy to read from the top,
bottom, and sides.
V +V
Output terminal on PLC
or other device
AC power
supply
*2
Input terminal
0-V terminal
COM terminal
Forget These
Worries with the
H5CZ
Stabilized DC
power supply
*2. The AC power supply ground is on the commercial power supply side.
Worry-free operation is
achieved with the H5CZ
by restricting the time
that can be set.

Other manuals for Omron H5CZ

Question and Answer IconNeed help?

Do you have a question about the Omron H5CZ and is the answer not in the manual?

Omron H5CZ Specifications

General IconGeneral
TypeDigital Timer
Time Range0.001 s to 9999 h
Output TypeRelay, Transistor
Power Supply100 to 240 VAC
MountingPanel
DisplayLED
Operating ModeON-delay, Interval, One-shot
Contact Rating5A at 250V AC
Number of Digits4
Control MethodDigital
Setting MethodDigital
Operating Temperature-10 to 55°C
Storage Temperature-25 to 65°C

Summary

Features

Better Readability

Character Height of 10 mm with a Wide Viewing Angle.

The Easiest Operation

Operation is simplified by the Up/Down Keys for each digit on 4-digit.

Safety and Reliability

Power supply and input circuits are isolated for safety and reliability.

Additional Features

Set Value Limit, Output Counter, Waterproof, Key Protection, New Modes.

Model Number Structure

Model Number Legend

Explains the symbols used in the H5CZ model number structure.

Ordering Information

List of Models

Details various H5CZ models based on time specifications, operating modes, and voltage.

Accessories (Order Separately)

Protective Covers (SoftHard)

Soft Cover for oil protection, Hard Cover for general protection.

Mounting and Protection Accessories

Flush Mounting Adapter, Waterproof Packing for installation and IP rating.

Connection Sockets and Terminal Covers

Sockets for front/back connection and terminal covers for safety.

Specifications

Ratings

Electrical and environmental specifications including voltage, power, time ranges, and output.

Inrush Current Characteristics

Provides reference values for inrush current during power ON.

Product Characteristics

Electrical, Mechanical, and Environmental Specs

Details accuracy, resistance, immunity, life, weight, and operating ranges.

Compliance and InputOutput Functions

Covers safety standards, EMC, and I/O signal handling.

Connections

Block Diagram and Terminal Arrangement

Visual representation of internal circuits and terminal layouts for different models.

Input Circuit Configurations

Details various input connection types like NPN, Open Collector, and sensors.

Input Signal Levels

Specifies voltage and impedance levels for different input signal types.

Nomenclature

Display Section Overview

Identifies and explains the timer's display elements and indicators.

Operation and Switch Functions

Describes the function keys and the key-protect switch.

Dimensions

Mounting and Panel Cutout Dimensions

Provides physical dimensions and panel cutout details for flush/surface mounting.

Dimensions with Accessories

Shows overall dimensions when using flush mounting adapter or front connecting socket.

Connection Sockets

Front-Connecting Sockets

Details P2CF-08 and P2CF-08-E sockets, including dimensions and terminal arrangements.

Back-Connecting Sockets and Covers

Details P3G-08 socket and Y92A-48G terminal cover for finger-safe construction.

Optional Products for Track Mounting

Mounting Tracks and Accessories

Details mounting tracks, end plates, and spacers for DIN track mounting.

Operating Procedures for Timer Function

Setting Time Range and Timer Mode

Guide for setting the time range and selecting the timer mode (UP/DOWN).

Configuring Output Mode and Time

Steps to set output modes, output time, and input signal width.

Setting InstantaneousTime-limit Output

How to set the function for instantaneous output.

Function Setting Mode Operations

Setting Set Value Limit and Key Protect Level

How to configure the set value limit and key protection levels.

Configuring Output ON Count Settings

Setting alarm and monitor values for output ON counts.

Explanation of Timer Functions

Core Timer Settings

Explains Time Range, Timer Mode, Output Mode, Output Time, and Input Signal Width.

Advanced Settings and Counters

Details Key Protect, Instantaneous/Time-limit, Set Value Limit, and Count Alarm/Monitor functions.

Operation in Run Mode

Displaying Present Value and Set Value

How present and set values are displayed during operation.

Understanding ON Duty Ratio and Cycle Time

Explains display of ON duty ratio and cycle time in Mode Z.

Timing Charts for Timer Operation

Signal ON Delay Modes (A, A-1)

Timing charts for Signal ON Delay 1 and 2.

Power ON Delay Modes (A-2, A-3)

Timing charts for Power ON Delay 1 and 2.

Timing Charts for Timer Operation (Continued)

Repeat Cycle Modes (b, b-1)

Timing charts for Repeat Cycle 1 and 2.

Timing Charts for Timer Operation (Continued)

Signal OFF Delay and Interval Modes (d, E)

Timing charts for Signal OFF Delay and Interval.

Cumulative and Flicker Modes (F, Z)

Timing charts for Cumulative and ON/OFF-Duty-adjustable Flicker.

Timing Charts for Timer Operation (Continued)

Stopwatch Mode (S)

Timing chart for the Stopwatch mode.

Timing Charts for Instantaneous Outputs

Power ON Delay (A-2) with Instantaneous Output

Timing chart for Power ON Delay with instantaneous contact output.

Repeat Cycle 1 (b) with Instantaneous Output

Timing chart for Repeat Cycle 1 with instantaneous contact output.

Timing Charts for Instantaneous Outputs (Continued)

Interval (E) with Instantaneous Output

Timing chart for Interval mode with instantaneous contact output.

Flicker (Z) with Instantaneous Output

Timing chart for ON/OFF-duty adjustable Flicker with instantaneous output.

Twin Timer Operation Procedures

Switching to Twin Timer Mode

Steps to switch the H5CZ from Timer to Twin Timer mode.

Setting Twin Timer Parameters

Guide for setting OFF time range, ON time range, and timer mode for Twin Timer.

Twin Timer Function Setting

Configuring InstantaneousTime-limit and Set Value Limits

Setting output function and upper limits for Twin Timer.

Setting Key Protect and Output Count Alarms

Configuring key protection and ON count alarm/monitor values for Twin Timer.

Twin Timer Function Explanations

Setting OFF and ON Time Ranges

Explains setting OFF and ON time ranges for Twin Timer.

Twin Timer Modes and Input Settings

Details Timer Mode, Twin Timer Output Mode, Input Signal Width, and Key Protect.

Twin Timer Timing Charts

Flicker OFF Start 1 Timing Charts (toff, ton)

Timing charts for Flicker OFF Start 1 and Flicker ON Start 1.

Flicker OFF Start 2 Timing Chart (toff-1)

Timing chart for Flicker OFF Start 2.

Twin Timer Timing Charts (Continued)

Flicker ON Start 2 Timing Chart (ton-1)

Timing chart for Flicker ON Start 2.

Instantaneous Output Timing Charts (toff, ton)

Timing charts for Flicker OFF Start 1 and ON Start 1 with instantaneous outputs.

TimerTwin Timer Selection Mode

Mode Selection Procedure

Guide to select between Timer and Twin Timer modes.

Key Protect Level Configuration

Understanding Key Protect Levels (KP-1 to KP-7)

Details the function and impact of each key protect level.

Self-diagnostic Function

Error Displays and Correction Methods

Explains how to interpret and resolve timer error messages.

Safety Precautions

General Handling and Installation Warnings

Warnings about metal debris, explosive gases, terminal tightening, and touching terminals.

Usage Environment and Mounting Precautions

Guidance on temperature, humidity, vibration, shock, and location suitability.

Precautions for Correct Use

Power Supply and Startup Considerations

Notes on DC power supply, inrush current, voltage stability, and startup behavior.

Environmental and Wiring Standards

Conformance to EN/IEC standards, insulation, and wiring guidelines.

Warranty and Application Considerations

Warranty and Liability Limitations

OMRON's warranty terms and limitations of liability.

Suitability and Disclaimer Information

Guidance on product suitability, performance data, and specification changes.

Related product manuals