H5CZ
19
Timer
Mode S: Stopwatch (Timer resets when power comes ON.)
Basic operation Detailed operation
The signal starts and stops timing.
The display is held and timing is continued if the reset
is received during timing operation.
The timer resets if the reset is received when the
timing operation is stopped.
Note: Output is instantaneous when setting is 0.
Power
Start signal
input
Reset
Display
(for elapsed
time)
*
flashes
*
Timing
RST
9999
Set time
0
Set time
0
UP
DOWN
Power
Start signal
Reset
Timing diagram
Output