Omron NJ/NX Controller Ethernet Connection via a Hub
7. Omron NJ/NX Controller Ethernet Connection via a Hub
7.1. Click Controller menu > Communications Setup as shown on page 14.
7.2. Click the "Ethernet Connection via a Hub" button as shown below.
7.3. Enter the IP address of the NJ/NX controller. The default address for an NJ/NX controller is 192.168.250.1.
7.4. Click "Ethernet Communication Test".
7.5. Be sure Test OK” shows in the white bar as shown above. This indicates that you have good
communications with the Omron controller.
7.6. Click "OK" when ready.