Lists hardware components for the NJ301 controller configuration.
Details the physical placement and mounting of ID-40 readers.
Configures custom read cycle parameters for trigger, capture, and end cycle.
Adjusts parameters for focused image and freezing part movement.
Selects barcode types to be read and disables unused ones.
Assigns specific IP addresses and subnets to each ID-40 reader.
Obtains and extracts the EDS file required for EtherNet/IP integration.
Details physical wiring and connections for controllers and HMI.
Chooses the correct SYSMAC project file for the hardware configuration.
Modifies device and version settings in SYSMAC Studio to match the controller.
Connects via USB, performs communication tests for controller setup.
Selects and configures Ethernet connection via a hub for controller communication.
Sets the controller IP address to match the reader subnet.
Creates global variables for storing ID-40 data for controller communication.
Defines data types for input and output assemblies for ID-40 communication.
Configures global variables for ID-40 input/output assemblies with Network Publish.
Establishes an online connection to the controller for project download.
Imports EDS file and configures EtherNet/IP connection settings in SYSMAC Studio.
Adds ID-40 devices to SYSMAC Studio by specifying IP, model, and revision.
Verifies controller communication and transfers the project configuration.
Monitors EtherNet/IP devices and checks connection status for errors.
Option to skip HMI panel setup if not included in the solution.
Selects the HMI controller and modifies its device and version settings.
Accesses and modifies the TCP/IP settings for the NA-HMI panel.
Establishes an online connection to the NA-HMI panel for project download.
Verifies synchronization options and transfers the project to the NA-HMI device.
Adjusts trigger position for fastest read times and optimal barcode reading.
Monitors ID-40 reader with WebLink to adjust image capture delay.
Sets the read timeout using the HMI interface by entering a value.
Sets the initial value of the ReadTime global variable in SYSMAC Studio.
Explains the use of the Min_OnTime timer for trigger signal management.
Specifies required trigger and end cycle settings for controller logic.