%1
7-1 Commands to Start and End Online Transfer
Note
All data values must be sent in ASCII code.
m
1
m
2
d
1
d
2
d
1
35 41
31 32 33
Example:
2-bit hexadecimal
5A
H
3-bit BCD
123
s
1
s
2
38 37
Check Sum
87
H
7-1-1 Online Transfer Start
Format
1B
[ESC]
78
x
Description
Notifies the PT that online transfer has started.
Whenthe PT receives this commandit interrupts Run operationandstands by to
receive commands from the host computer (Online Transfer mode).
Caution
An error occurs if the PT receives no further command within 5 seconds of re-
ceiving this command. An error message is displayed on the screen and the
buzzer sounds. Refer to the PT manual for details.
7-1-2 Online Transfer End
Format
1B
[ESC]
79
y
s
1
s
2
OD
[CR]
38
37
s
1
s
2
:
Checksum (fixed as 87
H
)
Description
Notifies the PT that online transfer has ended.
When the PT receives this command it exits the Online Transfer mode and re-
commences Run operation.
7-2 Commands to Set Transfer from PT to Host Computer
7-2-1 Specify Transfer Screen Number (Host Computer to PT)
Format
1B
[ESC]
73
s
m
1
m
2
(m
3
m
4
)
s
1
s
2
OD
[CR]
m
1
m
2
(m
3
m
4
):
Screen number to send from the PT
NT20M: 00
H
All screens
01 to FA
H
(2-digit hexadecimal)
NT600M: 0000
H
All screens
0001 to 03E8
H
(4-digit hexadecimal)
& $&
Section 7-2