EasyManuals Logo
Home>Omron>Servo Drives>R88D-KN10F-ECT-L

Omron R88D-KN10F-ECT-L User Manual

Omron R88D-KN10F-ECT-L
626 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #570 background imageLoading...
Page #570 background image
Appendices
A - 124
G5-series Linear Motors/Servo Drives With Built-in EtherCAT Communications
Event name Object Error Event code 14A9 0000 hex
Description The object area data in non-volatile memory is corrupted.
Source
EtherCAT Master Function Module
Source
details
Slave
Detection
timing
When
establishing
communications
after turning ON
power to the
slave
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling slave
power)
Log category
System
Effects
User program
Continues. Operation Power drive circuit is OFF for relevant slave.
Indicators
EtherNet/IP NET RUN EtherNet/IP NET ERR EtherNet/IP LINK/ACT
––
System
-defined
variables
Variable Data type Name
None
Cause and
correction
Assumed cause Correction Prevention
Noise Reset all of the objects. Take noise
countermeasures.
Reset all of the objects. Take
noise countermeasures.
Non-volatile memory failure If the error persists, replace the
Servo Drive.
None
Attached
information
None
Precautions/
Remarks
“36” is displayed on the Servo Drive front panel and F136 is given as the AlarmCode (4001 hex).
Event name Object Error Event code 14AA 0000 hex
Description The object area data in non-volatile memory is corrupted.
Source
EtherCAT Master Function Module
Source
details
Slave
Detection
timing
When
establishing
communications
after turning ON
power to the
slave
Error
attributes
Level
Minor fault
Recovery
Error reset
(after cycling slave
power)
Log category
System
Effects
User program
Continues. Operation Power drive circuit is OFF for relevant slave.
Indicators
EtherNet/IP NET RUN EtherNet/IP NET ERR EtherNet/IP LINK/ACT
––
System
-defined
variables
Variable Data type Name
None
Cause and
correction
Assumed cause Correction Prevention
Noise Reset all of the objects. Take noise
countermeasures.
Reset all of the objects. Take
noise countermeasures.
Non-volatile memory failure If the error persists, replace the
Servo Drive.
None
Attached
information
None
Precautions/
Remarks
“36” is displayed on the Servo Drive front panel and F236 is given as the AlarmCode (4001 hex).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-KN10F-ECT-L and is the answer not in the manual?

Omron R88D-KN10F-ECT-L Specifications

General IconGeneral
BrandOmron
ModelR88D-KN10F-ECT-L
CategoryServo Drives
LanguageEnglish

Related product manuals