What causes overvoltage in Omron R88D-KN02H-ECT-R Servo Drives?
- PPaul ColemanSep 12, 2025
An overvoltage in Omron Servo Drives occurs when the power supply voltage exceeds the allowable input voltage range. To address this, measure the voltage between the connector (L1, L2, and L3) lines and input the correct voltage. Remove the phase advance capacitor. Use a tester to measure the resistance of the external resistor between the B1 and B2 terminals on the Servo Drive; if the resistance is infinite, the wiring is broken, so replace the external resistor. You might also need to change the regeneration resistance and wattage to the specified values by calculating the regenerative energy and connecting an External Regeneration Resistor with the required regeneration absorption capacity and reducing the descent speed. If all else fails, replace the Servo Drive.